AqueenaPro WT-100
Installation and Repair manual
Rev. A
Installation and Repair Manual AqueenaPro WT-100
Page 54 of 64
1.
Remove water tank (40) firstly. Follow the instruction according chapter 19 Water tank (40).
2.
Unscrew two screws (66) and remove the leakage sensor.
3.
Dismount control box (24) from the filter platform and disconnect leakage sensor cable from the connector.
4.
Connect new leakage sensor to control board and assembly it back to its position.
5.
Place the leakage sensor (59) on the bottom of the device and secure with the screws.
6.
To close the device, follow the steps in reverse order.