AqueenaPro WT-100
Installation and Repair manual
Rev. A
Installation and Repair Manual AqueenaPro WT-100
Page 22 of 64
5.
Connect white tube to the pure water faucet from the bottom of the sink.
Before the tube will be inserted in to the faucet apply the protection against leakage according photos below.
6.
Other end of the tube connects to PURE WATER connector.
Note!
The pure water faucet can be mounted on the wall. Use the wall fixture as holder for the faucet.
7.8. Main Unit installation
1.
Verify if all connection are correct, no water leakage
2.
Install RO MEMBRANE WT-100-15 according chapter 7. RO MEMBRANE INSTALATION.
3.
Remove the power adaptor WT-100-46 from the accessories bag and connect it. Ensure that the power
cord plug is suitable for local power socket.
4.
Position the main unit under the sink.
5.
Bypass the water tank, close the water tank valve.
6.
Open inlet water main valve and water faucet.
7.
Switch on the AqueenaPro. As a start-up audio signal will be activated 1 buzz.
8.
Let water run through the system for aprox. (5-10 min system stabilization) and check all connections.
Caution!
If any leaks are found, do not proceed further until the leaks are fixed.
9.
Close the water faucet and check if flow of waste water (aprox. after 30 s) stops.
10. If no deviation or leakage was found, open the water tank valve and let fill the system with water.
11. Drain first two water tanks before use.
Note!
The first two tanks can contain black residues. It is carbon particles washing away from the carbon filter. It
will not affect future system performance or quality of purified water.