Page 45 of 64
5.
Unplug the leakage sensor cable from the connector.
Note!
Display cable (flat cable) is solder to PCBA. Never disorder the cable. The PCBA is deliver all the time
together with the display cable.
6.
Exchange the PCBA, connect leakage sensor cable and cable set in its connectors.
7.
Place the PCBA in to the box. Pay attention to correct position – side with components should be palce
inside of the box. Put lower cover (23) and assemble the control box (23+24) on its position.