background image

 

AqueenaPro WT-100 

Installation and Repair manual 

 

Rev. A 

Installation and Repair Manual AqueenaPro WT-100  

 

Page 14 of 64 

 

7. Product installation 

Note!  

1.  The AquuenaPro is a water filtration system for home use. Any use outside the indoor home environment 

and for purpose other than purifying water for household use will automatically void your warranty. 

 

2. 

The AqueenaPro should not be used on feed water that is microbiologically unsafe or unknown 

microbiological quality without disinfecting the water before using the device. 

 

3. 

Cold water plumbing – AqueenaPro must be connected to cold water pipe. If the hot water (>38°C) as 

water source will be used, it will cause permanent damages to RO membrane and severely degrades the 

product  

 

4. 

Plumbing and carpentering work is needed. 

 

5. 

Ensure, whether the main water supply is turned off before any plumbing work is stared! 

 

7.1. Pre-Installation Preparations 

To secure correct functionality and to keep long life time of the water purifier AqueenaPro, the place for the main 

unit should be consider and precisely chosen in prior, following recommendation should be followed: 

 

7.1.1.   Recommended side preparation 

 

Mains connection not more than 1.5 m from the point of installation of AqueenaPro 

 

Water supply not more than 3 m away   

 

Drain for rejected water not more than 3 m away 

 

Space as per dimensions of the AqueenaPro 

 

It is preferable to install the AqueenaPro near a sink so that inlet and reject water lines are easily available. 

 

Avoid sharp bends in the pipe. Do not bend or block the rejected water tube. 

 

Do not confine the AqueenaPro in a tight cabinet. 

 

 

 

 

 

 

 

Содержание AqueenaPro WT-100

Страница 1: ...INSTALLATION and REPAIR MANUAL AqueenaPro WT 100 REV A HomeArt 01 08 2014...

Страница 2: ...Note The repair manual may be changed updated due to modification on product Please always refer to the latest version which will be delivered to all authorized service centre and posted on web page W...

Страница 3: ...nformation 9 5 6 Product special features 10 5 7 Product characteristics 10 5 8 Product overview 11 6 Repair information 12 6 1 Warranty card 12 6 2 Note for ZCT users 13 7 Product installation 14 7 1...

Страница 4: ...e replacement procedure 31 10 Trouble shooting guideline 32 11 Tools 33 12 How to open AqueenaPro 34 13 Locking plate left and right 35 14 Inlet solenoid valve 33 36 15 Low pressure switch 22 39 16 Di...

Страница 5: ...n the service environment E g by pulling off a sweater shirt fleece walking shoes etc The handling of electronic components need s special attention regarding ESD All activities have to be done with E...

Страница 6: ...their products 3 Spare parts Only approved spare parts and consumables can be used for the product repair and maintenance Valid spare parts list is available to download from WebShop application under...

Страница 7: ...in water as rust sand and other solid impurities 2 Second stage Pellet Carbon filter WT 100 73 The Pellet Carbon filter can effectively adsorb free chlorine organic matter odours discoloration and ot...

Страница 8: ...he tablet is part only of freshly new filter and it is not accessible by end user service technician 5 3 Technical characteristic Model WT 100 Voltage AC100 240V 50 60HZ Power Rating 25W Dimensions mm...

Страница 9: ...38 bar 42 1000 mg L 2000 ppm 2 mg L 6 8 3 NTU at 3 5 bar feed water pressure and 25 o C feed water temperature at 3 5 bar feed water pressure and 25 o C feed water temperature TDS 750 ppm Measured on...

Страница 10: ...onment for the RO membrane Combined solenoid valve to flush the RO membrane automatically and controls waste water flow Inlet water solenoid valve which by definition opens or shuts inlet water pressu...

Страница 11: ...AqueenaPro WT 100 Installation and Repair manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 11 of 64 5 8 Product overview...

Страница 12: ...e customer loose rights to a warranty repair and the case will be treated as a non warranty 6 1 Warranty card Ensure if warranty card was filled properly before every repair The card is part of each u...

Страница 13: ...d contains following Correct serial number and lot number Serial number format PS013 nnnnnnnnnnnn optional information Note If the serial number being recorded use only numbers without letters only di...

Страница 14: ...nd severely degrades the product 4 Plumbing and carpentering work is needed 5 Ensure whether the main water supply is turned off before any plumbing work is stared 7 1 Pre Installation Preparations To...

Страница 15: ...d screwdrivers 1 of each Scissors 1 pair 14 16 mm wrench 1 19 21 mm wrench 1 Needle nose pliers 1 7 2 Installation Each unit is equipped with dummy plugs which must be removed before installation 7 3...

Страница 16: ...quick connector the ends must be straight and smooth Do not cut the tube under the angel To connect tube in to the quick connector follow next steps 1 Remove the locking clip 2 Put the tube inside 3 S...

Страница 17: ...ure that tubes are connected correctly after work is done Note Check size of pipe hose of the customer before installation As a standard accessories AqueenaPro has 1 2 inline feed water connector If p...

Страница 18: ...64 1 Close the main house inlet water source 2 Disconnect inlet water pipe tube 3 Assembly inline feed water connector and connect the tube pipe to the connector 4 Connect white tube to the feed wate...

Страница 19: ...naPro WT 100 Page 19 of 64 5 Connect the tube in to INLET WATER connector 7 6 Waste water pipe installation 1 Remove the clamp drain from the accessories bag 2 Drill 7 mm hole in the drain pipe under...

Страница 20: ...al Rev A Installation and Repair Manual AqueenaPro WT 100 Page 20 of 64 4 Ensure that tube is inserted correctly in to pipe see pictures below assembly the clamp to the pipe and secure it with screws...

Страница 21: ...ld be installed Note Certain space should be left between the hole and wall or edge of the sink Do not forget that the faucet must be accessible from the bottom of the sink as well 2 Drill an 14 mm ho...

Страница 22: ...connect it Ensure that the power cord plug is suitable for local power socket 4 Position the main unit under the sink 5 Bypass the water tank close the water tank valve 6 Open inlet water main valve a...

Страница 23: ...e AqueenaPro when the drain is blocked up 8 RO Membrane installation 1 RO membrane is not installed and it is separately packed in protective foil Remove the membrane WT 100 15 from the protective foi...

Страница 24: ...WT 100 15 Remove protective rubber caps from RO membrane Note Do not force the reverse osmosis membrane into the membrane shell it can result in permanent damage of the shell or membrane components Da...

Страница 25: ...ed before the RO housing is closed The sealing must be put on therear od the shell 6 Close the unit Note Verify all connections before the top cover is put back no water leakage Insert RO membrane wit...

Страница 26: ...tomatically flush for 18 seconds 9 2 Filter Replacement Time Note Filters and membrane are consumables Their replacement time is dependent on the quality of raw water and water consumption They are no...

Страница 27: ...he filters conditions and actual status is shown on the Filter Status Display CAUTION If the water purifier is not in daily use average use of 10L per day please refer to the table below The filters m...

Страница 28: ...cess If the answer is YES at least one of these 3 questions please exchange the filter s 9 4 The filters replacement procedure 1 Close the inlet water valve 2 Unplug the device from mains 3 Remove the...

Страница 29: ...e to quick connector and secure it with locking clip If the pellet carbon filter WT 100 73 and or PP filter 1 m WT 100 74 needs to be replaced unplug the PP filter m WT 100 72 firstly and remove all t...

Страница 30: ...er 9 Open the inlet water valve and switch on the power supply 9 5 After filter replacement Select button After the filters are replaced press the Select button to select the corresponding filter icon...

Страница 31: ...rocedure 1 Switch off the power supply 2 Close the inlet water valve 3 Remove the top cover 4 Unplug the old filter disconnect filter from quick connectors 5 Replace the filter Pay attention to correc...

Страница 32: ...nlet water solenoid valve is faulty no water can get in no pure water Replace the solenoid valve A pre filter is blocked Observe the pure water and waste water replace the pre filter Non return valve...

Страница 33: ...n return valve check whether there is water leakage in the pipelines The pure water flow is small or not flowing Pre filter is plugged Replace the pre filter RO membrane is plugged Wash or replace the...

Страница 34: ...self holding put the lock in unlocked position Left one is equipped by the spring WT 100 50 and it needs be hold in unlocked position during cover opening Self holding locking element WT 100 86 The lo...

Страница 35: ...WT 100 Page 35 of 64 13 Locking plate left and right Tools Philips screwdriver PH2 Spare part WT 100 86 Lock Right KIT 47 48 49 70 WT 100 87 Lock Left KIT 52 51 49 50 70 WT 100 69Tapping screw M3x12...

Страница 36: ...f 64 Note Only Lock Right KIT WT 100 86 pos 47 48 49 70 and Lock Left KIT WT 100 87 can be ordered Note Pay attention to correct locking plate Left and right are not same 14 Inlet solenoid valve 33 To...

Страница 37: ...nd Repair manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 37 of 64 Spare part WT 100 79 Inlet solenoid valve kit 1 Remove the top cover WT 100 01 2 Unscrew two screws Position of in...

Страница 38: ...pes 4 Disconnect two orange wires 5 Exchange the new inlet solenoid valve Note The solenoid valve 33 is delivered together with two connectors 76 5 Only Solenoid valve kit WT 100 79 is possible to ord...

Страница 39: ...T 100 Page 39 of 64 1 Plug water pipes and secure them with the locking clip 15 Low pressure switch 22 Tools Philips screwdriver PH2 Spare part WT 100 81 Low Pressure Switch kit 1 Remove the top cover...

Страница 40: ...t the low pressure switch 22 3 Disconnect two yellow wires 4 Unplug the water tube 5 Exchange the low pressure switch 22 Note Only Low Pressure Switch Kit WT 100 81 is possible to order Set contain lo...

Страница 41: ...ver PH2 Spare part WT 100 55 Display board WT 100 69 Screw M3x12 2 pcs WT 100 54 Display board WT 100 70 Screw M3x8 2 pcs WT 100 82 Display kit 1 Remove the top cover WT 100 01 2 Dismount 2 screws WT...

Страница 42: ...WT 100 Page 42 of 64 4 Release the flat cable form the set cut tie wrap 5 Disconnect the flat cable from the connector 6 Release the PCBA board WT 100 55 by removing two screws WT 100 70 7 Exchange t...

Страница 43: ...2 and washer If the panel label WT 100 57 is damaged scratched broken and it must be changed only display kit WT 100 82 panel label with the bracket can be ordered 17 Control board 24 Tools Philips sc...

Страница 44: ...Repair Manual AqueenaPro WT 100 Page 44 of 64 2 Remove 4 screws and release the box Note Do not lose lower cover 23 3 Remove the cable set from the connector 4 Disassembly the PCBA from the box by rel...

Страница 45: ...flat cable is solder to PCBA Never disorder the cable The PCBA is deliver all the time together with the display cable 6 Exchange the PCBA connect leakage sensor cable and cable set in its connectors...

Страница 46: ...ure it with 4 screws WT 100 65 Do not forget put plastic protection to reset buttons 9 Tide up the cable set inside of the device and ensure cables are not squeezed 10 Assembly the inlet solenoid valv...

Страница 47: ...allation and Repair Manual AqueenaPro WT 100 Page 47 of 64 1 Remove two screws WT 100 65 2 Unplug water pipes from the quick connectors disconnect white wires from the valve Front side Back side Flash...

Страница 48: ...oid valve Note Only flashing solenoid valve kit WT 100 80 can be ordered Pay attention to correct position of the flashing solenoid valve Note Do not forget apply locking clips to quick connectors 4 P...

Страница 49: ...naPro WT 100 Page 49 of 64 19 High pressure switch 28 Tools Philips screwdriver PH2 Allen key CH17 19 Spare part WT 100 83 High pressure switch KIT 1 Release water pipe from the plastic screw cup WT 1...

Страница 50: ...t two screws WT 100 66 and remove the high pressure switch 3 Disconnect two blue wires and exchange the high pressure switch 28 Note Only high pressure switch KIT WT 100 83 can be ordered Pay attentio...

Страница 51: ...ck to high pressure switch Note Do not forget insert blue pin before water pipe is connected to the switch 20 Water tank 40 Tools Philips screwdriver PH2 Spare part WT 100 40 2 5 G water tank WT 100 3...

Страница 52: ...anual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 52 of 64 2 Disconnect pipe from tank valve 41 3 Pull out outlet connectors 43 all three 4 Remove the filter platform and put it aside...

Страница 53: ...r pipe with water tank valve 41 from tank connector kit WT 100 85 7 Replace a new water tank 40 Note New spongy pad 35 and new anchor ear 36 must be replaced too Follow the steps in reverse order to a...

Страница 54: ...ter tank 40 2 Unscrew two screws 66 and remove the leakage sensor 3 Dismount control box 24 from the filter platform and disconnect leakage sensor cable from the connector 4 Connect new leakage sensor...

Страница 55: ...ual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 55 of 64 22 Pump 25 Tools Philips screwdriver PH2 Pliers Spare part WT 100 78 Pump Kit 1 Remove the whole filter platform 4screws from e...

Страница 56: ...al Rev A Installation and Repair Manual AqueenaPro WT 100 Page 56 of 64 3 Pull out outlet connectors 43 all three 4 Remove the filter platform and put it aside Note Pay attention to cable set do not p...

Страница 57: ...lation and Repair manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 57 of 64 6 Remove 3 set filter for better access to screws 64 27 and unscrew them 7 Remove the pump 25 8 Disconnect...

Страница 58: ...e the pump ATTENTION Pay attention how wires are connected Always connect red green black brown Use the clamps as protection To assemble the new pump back follows the steps in reverse order When water...

Страница 59: ...r Manual AqueenaPro WT 100 Page 59 of 64 23 Power cord extension 44 Tools Philips screwdriver PH2 Spare part WT 100 44 1 5A patch cord 1 Release the bracket 45 for better manipulation unscrew two scre...

Страница 60: ...d Repair Manual AqueenaPro WT 100 Page 60 of 64 2 Disconnect the brown and grey wires from cable set 3 Pull the cord 44 from the bracket 45 and exchange it 4 ATTENTION To connect the wires back pay at...

Страница 61: ...ation and Repair manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 61 of 64 24 Colour cable set 1 Unplug cables set from the control board connector 24 2 Disconnect 2 orange wires fro...

Страница 62: ...manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 62 of 64 3 Disconnect 2 yellow wires from low pressure switch 22 4 Disconnect 2 white wires from inlet flashing valve 32 5 Disconnect...

Страница 63: ...ed Always connect red green black brown Use the clamps as protection 7 Disconnect the power cord 44 ATTENTION To connect the wires back pay attention to correct pair grey red brown black Use clamps as...

Страница 64: ...o WT 100 Installation and Repair manual Rev A Installation and Repair Manual AqueenaPro WT 100 Page 64 of 64 e High pressure switch 28 blue f Pump 25 red green black brown g Power cord 44 grey red bro...

Отзывы: