AqueenaPro WT-100
Installation and Repair manual
Rev. A
Installation and Repair Manual AqueenaPro WT-100
Page 53 of 64
5.
Release the water tank by removing anchor ear (36) – unscrew 4 screws (68).
6.
Disconnect water pipe with water tank valve (41) from tank connector (kit WT-100-85).
7. Replace a new water tank (40)
Note!
New spongy pad (35) and new anchor ear (36) must be replaced, too.
Follow the steps in reverse order to assembly the water tank (40) back.
Do not forgot apply the locking clip to quick connector(s).
21. Leakage sensor (59)
Tools: Philips screwdriver PH2
Spare part: WT-100-59 Leakage sensor
WT-100-66 Tapping screw M3x10