![Zepro ZHD 1500-135 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/zepro/zhd-1500-135/zhd-1500-135_installation-instructions-manual_3457752060.webp)
ZHD 1500/2000-135/155/175
60
Specifications
www.zepro.com
Fig. 65. Maximum power consumption - Minimum recommended conductor cross sectional area
-
+
-
+
L
L
U
min
I
min
I
min
U
min
16.2
Maximum power consumption - Minimum recommended conductor
cross sectional area
Z 1500/2000 (200 bar)
Hydraulic unit 7050
12 volt
24 volt
Pump - Motor unit
245 A
135 A
Magnet (hydraulic unit)
4.2 A
2.1 A
Magnet (electric safety valve)
1.5 A
0.75 A
Solenoid
1.8 A
0.9 A
Minimum recommended conductor cross sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
1.5 mm
2
Supply cable, L < 8 m
35 mm
2
35 mm
2
Supply cable, L = 8 - 15 m
50 mm
2
35 mm
2
Supply cable, L > 15 m
-
50 mm
2
Battery
Min. capacity, I
min
(available for lift)
180 Ah
170 Ah
Min. voltage during operation, U
min
(at lift)
9 Volt
18 Volt
16.3
Battery maintenance
When storing for longer than 1 week, you are recommended to disconnect the lift from the bat-
tery via the main switch or by releasing the lift’s main fuse, in order to reduce the risk of the bat-
tery discharging. The length of time the vehicle can be stored without the battery’s charge level
becoming too low depends on the condition of the battery, the charge level before storage and
how much power the vehicle’s other components take from the battery. After a period of storage,
the battery must always be charged fully before operating the lift.
When installing the lift and when carrying out service and repair work, when the lift is operated
repeatedly without the vehicle being started and used, the battery charger must be used be-
tween operations to maintain the battery’s charge level.
The battery charger must not be connected when operating the lift. Risk of damage.
NOTE.
Ensure that the lift has
access to the minimum
recommended power
capacity (I
min
)
.
Some ve-
hicles have restrictions
regarding the amount of
power the lift can access
from the existing battery.
NOTE.