Z3N/Z3NU/Z3NN/Z3NNU/Z3NW/Z3NWU 75-100
54
Testing and verification
www.zepro.com
11.2.4
Dynamic load (Test load 1.0 x tail lift loading capacity). For tail lifts with
load centre of 750 mm
Capacity
Load 1000 kg
Load 1500 kg
Distance out in platform (L)
1000 kg
750 mm
-
1500 kg
1125 mm
750 mm
2000 kg
1500 mm
1000 mm
2500 kg
1875 mm
1250 mm
11.3
Test of safety functions
The tail lift functions must be tested.
Check:
•
That the red light in the vehicle cabin turns off when the platform is completely closed against the body and
that it turns on when the platform is opened (where applicable).
•
That the tail lift will not operate if the cabin switch is in the off position.
• That the tail cannot be operated when the main current fuse is removed (where applicable).
•
That the overflow valve is activated when the lift is run up to the floor level or arm stops.
• That the tail lift cannot be lowered or tilted down respectively if the electrical connector from the lift and tilt
cylinders' respective electricity safety valve is removed.
• That the platform's max load marking has been included and is correctly positioned according to the loading
diagram for the tail lift model concerned.
•
That the warning flags are installed and fulfil their function correctly.
• That all safety and operating stickers are installed in their respective position.
• That the platform's mechanical lock functions correctly (where applicable).
• That the Operator's Handbook has been left in the driver's cabin
•
That the declaration of CE conformity has been filled in (where applicable).
Содержание Z3N 75-100