ZS SPAN INSTALLATION MANUAL FOR RAIL-BASED APPLICATIONS - U.S.
Step 2:
Install Roof Attachments
Remove Identified Roof Tiles
2a
Preserve tiles for later re-installation. (Roof sheathing not
shown)
Rafter
Install Attachment
2b
Follow manufacturer’s instructions for Zep
Solar-approved Tile Hooks or standoffs.
The Adjustable Mighty Hook from Zep
Solar, Inc. can be shifted off-center.
The hook portion of the
Adjustable Mighty Hook
can be shifted as well.
For extreme off-center placement,
roof sheathing and additional deck
screws are required.
Minimum rafter penetration
for Adjustable Mighty Hook lag
screw is 2.5”
Some Tile Hooks allow
adjustment of the hook
depth.
Tile Hook Placement
Replace Roof Tiles
2c
Tiles may require grinding in
order to fit flush.