Normal
: to perform the door opening, the output needs to be activated.
Inverted
: to perform the door opening, the output needs to be deactivated.
Security
: the output works in inverted mode but a security relay module
has been installed and therefore a specific pulse sequence is necessary
for the door opening (this requires the ZVP-ACSR module).
Switch Codes
: codes that will allow activation of the switches by typing them
into the keypad (only for the ZVP-KEYPAD or ZVP-TOUCHD modules). Code
activation time profiles can also be applied (see section 3.2.2.1).
State Signalling
: sets the type of the acoustic feedback to be performed on
the activation of the relay. Either a short or long beep can be configured.
Synchronisation
: enables switch synchronisation so that, when one of the
switches is activated and after a parameterisable delay, another switches
gets activated as well.
3.1.5
BUTTONS MODULE CALL CONFIGURATION
(HARDWARE/BUTTONS)
This section defines the buttons and the dwelling linked to each one of them, in case a
buttons module has been attached to the system (reference ZVP-NAME5).
Figure 15
Buttons