Securel v3
Technical Support:
13
pairing is to ensure that the communication between these devices is exclusive, i.e.,
that Securel v3 only responds to door opening commands from the access control
module to which is paired.
To pair a Securel v3 with an access control device:
If
Securel v3 has not been paired
with any device before, it will be in pairing
mode. Only connect the Securel v3 to the device desired to pair with and they
will be automatically paired.
If
Securel v3 is paired
, press the
“PAIR” button for three seconds to remove
the pairing. Securel v3 is then in pairing mode. Connect the Securel v3 to the
device desired to pair with and they will be automatically paired.
Figure 5.
Securel v3
– Physical button.
For more information of the LED status during pairing, see section 1.3.
Notes
:
Whenever Securel v3 is not paired, it will try to get paired by keeping the
pairing mode active.
While Securel v3 is in pairing mode no action can be performed in the output
on the serial channel.
Additionally, the serial channel can be locked at operating time so that any door
opening command transmitted from the access control module will be ignored while the
serial channel is locked.