The
opening object
is configured from the
“General” tab (see section 2.1) and the
following parameters are available:
Figure 4.
Opening Object - Configuration
Opening Object
[
disabled/
enabled
]
:
enables the “
[Access] Open Door
”
one-bit object, which activates the door opening.
Important:
To ensure the inviolability of the system, this object should be
associated with a group address configured as secure.
➢
Value
[
0/
1
]: value to be sent to trigger the door opening.
Opening Object Lock
[
disabled
/enabled
]:
enables the 1-
bit object “
[Access]
Lock Opening Object
” which locks the action of the opening object
(
“
[Access] Open Door
”).
➢
Lock Object Polarity
[
0 = Unlock; 1 = Lock /
0 = Lock; 1 = Unlock
]:
defines the value to send to lock/unlock the door opening via object.
➢
State After Download
[
Unlock
/ Lock
]: defines whether, after an ETS
download, door opening through object is to be initiated locked or
unlocked.