Securel v3
Technical Support:
11
➢
Heartbeat
(Periodical
Alive
Notification)
[
disabled
/enabled
]:
incorporates a one-
bit object to the project (“
[Heartbeat] Object to Send
‘1’
”) that will be sent periodically with a value of “1” to notify that the device
is still working (still
alive
).
Figure 3.
Heartbeat.
Note
:
The first sending after download or bus failure takes place with
a delay of up to 255 seconds, to prevent bus overload. The following
sendings match the period set.
➢
Manual Control
[
enabled
/disabled
]
: enables or disables the “Manual
Control” tab on the left menu. See section 2.1.1 for more details.
2.1.1
DOOR OPENING OBJECT
Securel v3 features a KNX object for door opening.
The access control module (for example, IWAC Out in the diagram in Figure 2),
through this object, will send opening commands to the Securel v3 that will trigger
timed closures of the relay (i.e. the opening of the door and its subsequent closing after
the opening time. See section 2.1).
Although the KNX door opening object can be associated with a non-secure group
address, to ensure the inviolability of the system, setting it as a
secure object
is highly
recommended, which will require, that the control device object (e.g., IWAC Out) is also
secure. For detailed information about the functionality and the configuration of the
KNX Secure, please refer to the specific manual “
Security KNX
” available in the
Securel v3 product section at the Zennio website (
Additionally, the door opening by object can be locked or unlocked at operating time.
As long as the lock is active, opening commands received through this object will be
ignored.