Securel v3
Technical Support:
7
Figure 2.
Access Control System connection diagram.
It should be recalled that, to ensure the inviolability of the access control
system, in the case of serial communication with the access control module, it
is necessary to locate the Securel v3 inside the room of the management
module.
Manual control button (7):
button for direct control of the output during the
installation process. See section 2.2.
Test/Prog. Push button (8):
a short press on this button sets the device into
the
programming mode
.
Note
: i
f this button is held while plugging the device into the KNX bus, the
device will enter into safe mode. Once the device enters into safe mode, a
long press (10 seconds) reset the device to factory defaults.
LED indicators:
indicator lights showing the status of the device:
➢
Pairing LED (2):
•
Securel v3 not paired
LED: Flashing
blue
.
•
Securel v3 paired or serial channel disabled
LED: Off
➢
Output Status LED (6):
•
Relay open (door closed)
LED: Off.
SECURE ZONE
IWAC Display v3
24VDC Power Supply
24VDC Electric Strike
Securel v3