background image

User Information

  

Safety Relays from IDEM           SEU-1 

H04 

Ver. A 

E61-326-00 

 

Correct Use 

The  SEU-1  contact  block  in  combination  with  any  basic  device 
from  the  IDEM  SCR  series  can  be  used  to  produce  up  to  three 
additional safety contact paths per device. An existing system can 
thus  be expanded  practically  indefinitely  in  a modular  manner. 
Activation takes place via a safety contact of the basic device, the 
SEU-1  provides  signaling  contacts  for  fault  monitoring.  The 
devices can be used in machines and systems up to safety cate-
gory 4, PL e according to EN ISO 13849-1. 

Features 

• 

3 safe, redundant relay outputs 
1 auxiliary contact (fault monitoring) 

• 

Activation via basic device from the IDEM SCR series 

• 

Modular, freely configurable safety system 

• 

Fault monitoring by basic device 

• 

Earth fault monitoring 

• 

Indication of the switching state via LED 

• 

Up to category 4, PL e, SILCL 3 

Function 

The safety expansion module SEU-1 in combination with a 
basic  device  from  the  IDEM  SCR  series  is  designed  for 
safe  isolation  of  safety  circuits  according  to  EN  60204-1 
and can be used up to safety category 4, PL e according to 
EN ISO 13849-1. 

Terminal  S11  (DC  24  V  control  voltage)  is  connected  with 
terminals S15 and S16 via the safety contacts of the basic 
device. Starting the basic device also activates the SEU-1. 
The basic device disconnects the control voltage when the 
safety  switch  is  operated,  and  the  safety  contacts  of  the 
SEU-1 open immediately. 

If a fault occurs in the SEU-1, this is detected by the basic 
device via terminals S23 and S24. 

Independent  operation  without  basic  device  is  not 
possible

Electrical  
Connection 

• 

When the 24 V version is used, a control transformer 
according to DIN EN 61558-2-6 or a power supply unit 
with electrical isolation from the mains must be connect-
ed. 

• 

External fusing of the safety contacts (6 A gG) must be 
provided. 

• 

A maximum length of the control lines of 1000 meters 
with a line cross section of 0.75 mm

2

 must not be ex-

ceeded. 

• 

The line cross section must not exceed 2.5 mm

2

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Open-
ing the device will void the warranty. 

Installation 

As per EN 60204-1, the device is intended for installation in 
control  cabinets  with  a  minimum  degree  of  protection  of 
IP54.  It  is  mounted  on  a  35  mm  DIN  rail  according  to  DIN 
EN 60715 TH35. 

Safety  
Precautions 

Fig. 1 Block diagram SEU-1 

Fig. 2  Installation / removal 

Fig. 3  Connections 

A1:  

Power supply 

A2 : 

Power supply 

S11:  

DC 24 V control voltage 

S10:  

Control line 

S15: 

Control line 

S16: 

Control line 

S23: 

Fault monitoring 

S24:    

Fault monitoring 

13-14: 

Safety contact 1 

23-24: 

Safety contact 2 

33-34: 

Safety contact 3 

13 23

14 24

K 2

K 1

33

34

S 2 3

S 2 4

SEU-1

(not for plug-in terminals) 

• 

All relevant safety regulations and standards are to be 
observed. 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage. 

• 

Note down the version of the product (see label “Ver: x”) 
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of 
the control system in which the device is incorporated 
must be validated again by the user. 

• 

Installation and commissioning of the device must be 
performed only by authorized personnel

• 

Observe the country-specific regulations when installing 
the device. 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost. 

• 

It is not allowed to open the device, tamper with the 
device or bypass the safety devices. 

Содержание SEU-1

Страница 1: ...ed External fusing of the safety contacts 6 A gG must be provided A maximum length of the control lines of 1000 meters with a line cross section of 0 75 mm2 must not be ex ceeded The line cross section must not exceed 2 5 mm2 If the device does not function after commissioning it must be returned to the manufacturer unopened Open ing the device will void the warranty Installation As per EN 60204 1...

Страница 2: ...d wiring space Category 4 PL e according to EN ISO 13849 1 is thereby possible If this fault cannot be ruled out category 3 PL e is achieved Applications Fig 3 Feedback Loop Contactors connected to the SEU 1 or the basic devices are monitored via the feed back loop of the basic device KA and KB are the positively driven contacts of the connected contactor or expansion module Wiring Feedback Loop F...

Страница 3: ...ing DIN rail according to EN 60715 TH35 Note Additional data can be requested from the manufacturer for applications that deviate from these conditions Safety Characteristics According to EN ISO 13849 1 The device is certified according to EN ISO 13849 1 up to a Performance Level of PL e Device cannot be switched on again after an emergency stop Check whether the emergency stop circuit was closed ...

Страница 4: ...ew terminals SEU 1 AC 230 V 50 60 Hz plug in terminals SEU 1 AC 115 V 50 60 Hz plug in terminals SEU 1 AC DC 24 V AC 50 60 Hz plug in terminals IDEM SAFETY SWITCHES Ltd 2 Ormside Close Hindley Industrial Estate Hindley Green Wigan WN2 4HR UK Tel 44 0 1942 261000 Fax 44 0 1942 676293 IDEM U S A 3909 Washington Blvd 204 Fremont CA 94538 email sales idemsafety com web www idemsafety com Feb 16 Fixed ...

Отзывы: