DALIBOX Broadcast 6CH/4CH

 

http://www.zennio.com

 

 

Soporte técnico:

 

http://support.zennio.com 

 

Contents 

1  Introduction .......................................................................................................................... 3 

1.1 

DALIBOX Broadcast 6CH ................................................................................................ 3 

1.2 

Installation ..................................................................................................................... 5 

1.3 

Compatible Ballasts ....................................................................................................... 6 

2  Configuration......................................................................................................................... 7 

2.1 

General Configuration ................................................................................................... 9 

2.2 

Channels ...................................................................................................................... 13 

2.2.1 

Main Configuration ............................................................................................. 13 

2.2.2 

Limits ................................................................................................................... 16 

2.2.3 

Switch On/Off ..................................................................................................... 17 

2.2.4 

Dimming .............................................................................................................. 18 

2.2.5 

Error Objects ....................................................................................................... 20 

2.2.6 

Status Objects ..................................................................................................... 23 

2.2.7 

Custom On/Off .................................................................................................... 24 

2.2.8 

Timers ................................................................................................................. 25 

2.2.9 

Scenes/Sequences .............................................................................................. 29 

2.2.10 

Lock ..................................................................................................................... 33 

2.2.11 

Custom Initialisation ........................................................................................... 34 

2.2.12 

Modes ................................................................................................................. 35 

ANNEX I. Error indicators ............................................................................................................ 40 
Annex I. Communication Objects ................................................................................................ 41 

 

Содержание DALIBOX ZDI-DLB6

Страница 1: ...DALIBOX Broadcast 6CH 4CH KNX DALI Interface for 6 4 Channel Broadcast Control ZDI DLB6 ZDI DLB4 MANUAL DE USUARIO Application Program Version 1 0 Manual Edition 1 0 _a www zennio com...

Страница 2: ...6 2 Configuration 7 2 1 General Configuration 9 2 2 Channels 13 2 2 1 Main Configuration 13 2 2 2 Limits 16 2 2 3 Switch On Off 17 2 2 4 Dimming 18 2 2 5 Error Objects 20 2 2 6 Status Objects 23 2 2...

Страница 3: ...Support for up to 20 ballasts per channel and therefore up to 120 ballasts 6CH model or up to 80 ballasts 4CH model in total 110V or 230V power supply Ballast swap with automatic address re assignment...

Страница 4: ...ugh the on board pushbuttons and LEDs Figure 1 DALIBOX Broadcast 6CH Note certain figures or sections of this manual may refer specifically to DALIBOX Broadcast 6CH However please bear in mind that ev...

Страница 5: ...s button is held while plugging the device into the KNX bus the device will enter into safe mode In such case the LED will blink in red every 0 5 seconds Output Channels 1 slots for the connection of...

Страница 6: ...uorescent lamps may cause the remaining lamps flash briefly Fluorescent lamp ballasts need an extra time to switch off the load when a non immediate regulation to 0 is commanded Certain ballast models...

Страница 7: ...es being possible to modify them through communication objects Up to three different dimming times are available Dimming limits i e maximum and minimum lighting levels Minimum luminosity level reachab...

Страница 8: ...p failure Special operation modes Standby mode that allows notifying an external actuator after switching off a channel so the power supply to the ballasts in such channel can be interrupted thus redu...

Страница 9: ...nnel Manual operation can be done in two different ways named as Test On mode for testing purposes during the configuration of the device and Test Off mode for a normal use anytime Whether both only o...

Страница 10: ...will be contrary to that of the previous regulation although the first time the regulation will always be upwards unless the current level is already the maximum one in such case the regulation will...

Страница 11: ...om the KXN bus related to the channel operation will be ignored Moreover the device will not send the status objects that may correspond to the manual actions performed by the user The only exceptions...

Страница 12: ...l Control parameter provides an optional procedure for locking the manual control in runtime When this checkbox is enabled object Manual Control Lock turns visible as well as two more parameters Value...

Страница 13: ...ng value and the maximum dimming value will take the proportional part of the parameterised dimming time which must be understood as the time corresponding to the entire transition from 0 to 100 Bus f...

Страница 14: ...cking and unlocking the output channel i e disabling the control See section 2 2 10 Custom Initialization permits setting the initial state of the channels or after a KNX bus failure See section 2 2 1...

Страница 15: ...ch off or Defined Value the ballast will switch to a customisable value between 0 and 100 Figure 4 Channel x Configuration Functions checkboxes for enable or disable several additional functionalities...

Страница 16: ...percentage of 1 Economic Mode maximum luminosity level the ballast will be allowed to reach It determines the actual luminosity level that will correspond to a dimming percentage of 100 Dimming Limit...

Страница 17: ...imming Limits Minimum Dimming Value the available range is 0 to 100 Maximum Dimming Value the available range is 0 to 100 2 2 3 SWITCH ON OFF DALIBOX Broadcast 6CH 4CH lets configuring the general On...

Страница 18: ...Last On Value default option or Defined Value In case of selecting Last On Value o Reach Maximum after a Switch On Order if it s Already On enables or disables the option to switch to the maximum dimm...

Страница 19: ...e object is provided for the reception of the absolute dimming orders For both dimming modes the dimming time for the 0 to 100 transition may be selected among the three different dimming times alread...

Страница 20: ...resent errors 2 2 5 1 SHORT CIRCUIT ERROR DALI ERROR The short circuit error or DALI error is reported in case the communication is interrupted in the output channel due to issues in the DALI bus In s...

Страница 21: ...pected in the installation Note the connection of a high number of ballasts may also be detected as a short circuit see section 2 2 5 1 2 2 5 4 OPEN CIRCUIT ERROR The open circuit error indicates the...

Страница 22: ...e current number of ballasts as correct To replace an erroneous ballast with a new ballast it is advisable to wait for the detection of the ballast error and to connect the new ballast only after havi...

Страница 23: ...the Cx Error Lamp Failure object which will be sent periodically with value 1 in case of detecting a lamp failure in at least one of the ballasts connected to the channel After the error is over it w...

Страница 24: ...ming value between 0 and 100 whenever it changes Enabling this parameter brings up an addition one Sending Period defines the sending cycle time 1 to 255 seconds of the status object during a dimming...

Страница 25: ...orementioned object Dimming Value for Bit Value 1 sets a specific dimming percentage 0 to 100 to be applied to the channel when a 1 is received Dimming Time for Bit Value 1 At Once Dimming Time 1 Dimm...

Страница 26: ...in this case On the other hand the flashing function consists in switching the channel on and off a certain number of times or indefinitely according to the parameters once the corresponding object i...

Страница 27: ...before being automatically switched off unless the value 0 is received through Cx Simple Timer which will switch the channel off immediately in the range 0 to 255 seconds or minutes The value 0 defau...

Страница 28: ...g time immediate Assuming that the 1 labels correspond to the arrivals of the value 1 through the Cx Simple Timer and that the 0 labels correspond to the arrival of the value 0 the expected behaviour...

Страница 29: ...ge during the sequence in the range 1 to 255 seconds or minutes Repetitions sets the number of iterations of the sequence between 0 and 255 The value 0 default option causes an endless repetition unti...

Страница 30: ...rformed or restarting the one currently running by sending the value 1 as well as interrupting the current sequence value 0 Note the Cx Start Stop Sequence object only applies to sequences and has no...

Страница 31: ...ype At Once Dimming Time 1 Dimming Time 2 Dimming Time 3 See section 2 2 1 In this case it will be also possible to save scenes If a scene saving order values 128 to 191 is received the current dimmin...

Страница 32: ...out the Action the dimming speed will adapt so that transition lasts for all the action time configured Action time defines the duration of the action i e the time it will take until the next action b...

Страница 33: ...bit object which will allow locking and unlocking the related channel Channel locking causes that any bus orders addressing to that channel are ignored Receiving a lock order while running a sequence...

Страница 34: ...vious State to recover the status previous to the lock order and Last Order to apply the status corresponding to the last order received during the lock state in case of not having received any order...

Страница 35: ...ed Value the channel will start at a specific dimming level between 0 and 100 configured in Value Send Status if enabled the status objects will be sent to the bus at the start up to inform about the...

Страница 36: ...s inactive to make it possible that the ballasts are powered during their initialisation Some other situations imply sending the Standby object A power supply error A short circuit error DALI error Du...

Страница 37: ...steadily switched on for at least the configured time it will only be possible to switch the loads off or to regulate them to 100 In case of having configured any limits either luminosity limits or d...

Страница 38: ...tomatic switch off of the channel if it is found to be steady i e without receiving further dimming orders at a certain dimming value or threshold for at least a certain amount of time configurable Th...

Страница 39: ...value for more than the threshold time Threshold Time time count before triggering the Auto Off mode between 1 255 seconds or minutes 10 seconds by default Burn in allows enabling the Burn in function...

Страница 40: ...ply Error notified through a specific LED Figure 23 Power Supply Error Channel dependent errors channel errors are indicated through the LED corresponding to the channel The error can be identified by...

Страница 41: ...Dec by 100 0x2 Dec by 50 0x3 Dec by 25 0x4 Dec by 12 0x5 Dec by 6 0x6 Dec by 3 0x7 Dec by 1 0x8 Stop 0x9 Inc by 100 0xA Inc by 50 0xB Inc by 25 0xC Inc by 12 0xD Inc by 6 0xE Inc by 3 0xF Inc by 1 Cx...

Страница 42: ...C W DPT_Start 0 1 Cx Burn in Mode 0 Stop Burn in 1 Start Burn in 20 44 68 92 116 140 1 Bit O C T R DPT_State 0 1 Cx Burn in Mode Status 0 Burn in Inactive 1 Burn in Active 21 45 69 93 117 141 1 Bit O...

Страница 43: ...tus consultas sobre los dispositivos Zennio http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com...