72
73
Commands
save device-edid
Saves the EDID of the downstream sink to the
srv/ftp/files
folder on the Management
Server. Executing this command will generate two file types:
.bin
and
.txt
. The
.bin
file is the EDID is standard format. The
.txt
file is the decoded EDID data.
See
Using Custom EDID Data (page 49)
for more information on using this command.
Syntax
save device-edid
id
file
Parameters
id
Type:
STRING or MAC Address
The name or MAC address of the decoder that is connected to the sink
device. String names are case-sensitive.
file
Type:
STRING
The name of the EDID file. Two files will be created using the
file
name:
.txt
and a file with no extension.
Example
save device-edid 0:1e:c0:f6:a5:2f myEDID
Success
Related Commands
load encoder-edid
set server auto-edid-mode
Advanced Operation
restore device
Delete all the config settings for specified device and restore it based on the information
stored in the database.
Syntax
restore device id
Parameters
id
Type:
STRING
or
MAC Address
The name or MAC address of the device. String names are case-sensitive.
Example
restore device myEncoder2
Success
restart device 0:1e:c0:f6:cb:76
Success
Related Commands
restart serverdevice