Check that the value of the consumption
remains constant
*
as the power supplied by the battery increases during
discharge.
8) The power taken from the
grid should decrease by an
amount equal to the power
supplied by the battery.
The photovoltaic system
remains at zero.
9) Once the photovoltaic system has been activated, check that:
The value of consumption remains constant as the photovoltaic
power increases.
Depending on the photovoltaic production, the
system will work according to the
modes described in Chapter 6.
Note
: if the four conditions above are not met,
check the positioning of the CTs
7) Once the countdown is over, the batteries will start to
deliver power according to the availability towards the utility,
trying to reset the consumption from the grid.
*
Check that the power of the loads in use does not change:
•
Heat pump or pump → load variable over time
•
Light or Hairdryer → load constant over time
10) Compare the value of the photovoltaic power shown on the storage inverter's display with that indicated
by the photovoltaic inverter, making sure that they are almost equal.
Waiting time
300 s
Discharg
e
Discharge
Charge
Normal