The Engineering menu is where Nova’s operations settings are adjusted from.
Compressors
Compressor Enable
Placing an X in the matrix will enable the compressor for that card track or output
bus. Please note that input compressors are enabled in the input setup menu for
the specific input.
Compressor Parameters Set
This is where the compressor parameters are set for the outputs, card tracks and
input parameters. The attack, decay, threshold, and ratio settings can be
adjusted. Makeup gain can be added to the output and card compressors if
desired.
Levels
Internal & External Slate Levels
This is where the internal and external slate microphone levels are adjusted. The
levels are independently adjustable in 1 dB steps from -12dB to 21dB.
Extra Input Gain
The extra input gain adds 10dB of digital gain to the analog inputs. The extra
input gain is global, meaning that when engaged the gain is applied to all analog
XLR inputs.
TA5 Output Levels Adjust
This menu manages the output audio levels for the TA5 output connectors. Each TA5 connector can carry 2
outputs. Each output can be independently adjusted to one of the following output levels:
•
0dBu
- Line Level
•
-10dBu
- Tape / Consumer Level
•
-35dBu
- Mic Level