![Yueming MC180-D-A Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/yueming/mc180-d-a/mc180-d-a_product-manual_3665118041.webp)
33
of the spiral movement. Swab control when dragging drag speed and strength, left behind a swab of liquid
can evaporate immediately, so it cannot leave streaks, as shown in Fig 4-1.If still can not remove the
pollution, please go to step
③
Fig.4-1
mirror cleaning
A: movement direction for cotton swab
B: movement track for cotton swab
③
for moderate pollution (saliva, oil) of the lens to the cleanness of moderate intensity
USES distilled white vinegar soak a unused degreased cotton swabs, cotton swabs with slight pressure to do
from the center of the circle to the outside of the spiral movement (see operating technique step (2), with an
unused degreased cotton swabs to wipe the lens on the extra distilled white vinegar. With an infiltrating
acetone degrease cotton swabs gently wipe the surface of the lens, remove all of the acetic acid, please go to
step
④
④
for severely contaminated (splash) lenses must try super clean
After fully shaking the container which fill with polish, open the container, dropout 4 or 5 drops, Drop in
cotton ball. move the cotton ball as draw circle path, when process please do not press the cotton ball,
continuously rotate the mirror, avoid the over polish ,the time no over 30 seconds. during this process, once
find the color changed , must stop the operation, changed color, means the coting film damaged.
A.
After use polish, use an unused degreased cotton swabs infiltration with distilled water. And then clean
the mirror surface. Thoroughly wet the lens surface, remove the polishing residue as much as possible,
do not make the lens surface becoming to dry, because it will be hard to remove the polishing residue.
NOTE
Must control the operating strength, force will damage the lens
coating film
Attention
Only the lens in use process by high levels of pollution, and perform steps 1, 2, 3, still
failed to achieve acceptable cleaning effect. This method can be used.
If removed the coating film, the performance of the lens will be completely
destroyed. If the color of the lens has obvious changes, the coating has been
completely destroyed.