31
Chapter4.
System Maintenance
Stable and normal operation of the machine is inseparable from the proper operation and routine maintenance.
This chapter describes the routine maintenance of the equipment.
4.1Mechanical maintenance
4.1.1
Lubrication of transmission parts
When the machine is in use, the main task of maintenance is to lubricate the components. The lubricating
positions include the connections of the trapezoidal screw and nut of the optical lifting frame and linear rails and
sliders of the lifting frame. The lubrication time depends on the operating environment of the machine. If the
environment is dusty, conduct maintenance every half month; in general, conduct maintenance once per month,
i.e., clean the lubrication sections and lubricate.
4.2Electrical maintenance
4.2.1
Electrical components
The machine frame is equipped with electrical control components inside, and there should be no debris in the
control box. It shouldn’t be uses as "toolbox" or "locker".
After running 1~2 months (if in harsh environments or the processed materials are dusty, the dust clean-up
period should be once a week), blow and clean the electric control box with clean dry air; keep the inside of the
control box clean to prevent failure of the electrical equipment caused by too much dust.
After running half a year, check and fasten the wiring of the electrical components with a screwdriver to prevent
loose and falling of the wire.
4.2.2
Emergency Stop button
Emergency Stop button is safety emergency components for laser marking machine, property related to
personnel and equipment safety. Must be within the provisions of this operating manual maintenance interval
according to the following steps to test the its function
Switch on laser marking machine, and process the work.
Press on the Emergency stop button, if all the power for the machine is cut off ,means the emergency
stop button in function, if one machine with two or more than two emergency stop button, need check
it one by one.
Reset Emergency button, the device will be restart.
Emergency stop button is one optional device, whether have this device need check the configuration.