![Yueming MC180-D-A Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/yueming/mc180-d-a/mc180-d-a_product-manual_3665118034.webp)
26
Fig.3-12
Galvanometer Side Plate Removing Diagram
The entire side plate of the galvanometer needs to be removed only for preliminary light adjustment. If the
dynamic axis needs to be adjusted to change the marking format when the optical path has been adjusted,
just open the box portion shown in Figure 3-12 and adjust the dynamic axis.
The laser path has been adjusted in the factory. However, prolonged transport or violent shaking may lead to
changes in laser path, so when the machine arrives at the client site, and preparation for laser path
adjustment is done, check if the laser path changes according to laser path calibration 1 and laser path
calibration 2 according to section 3.3.3.1.3. If there are any changes, adjust the laser path according to
section 3.3.3.1.2 and3.3.3.1.3; if there are no changes, follow section3.3.3.1.4 directly.
3.3.3.1.2
3D reflector
Fig.3-13
3D Reflector
To ensure that the transmitting direction of the laser beam is parallel to the corresponding axial direction
and the transmission process is accessible, the optical path should be adjusted when the optical lenses are first
installed. The outer optical path doesn’t need to be re-adjusted after the lenses are removed and washed because
the reflector holder of the outer optical path uses a more advanced design. As shown in Figure 3-13, the reflector
0
Y
X
0