13) Normal “RUN”, 
setting gap and 
calibration, but splicing 
is abnormal. 

1.

 

Regard “TEST” as 
fusion key 
wrongly. 

2.

 

Too large current. 

3.

 

The value of 
pushing is too 
small or is zero 
because of too 
high push speed. 

4.

 

The board is not 
put well. 

5.

 

On the right is bad 
tail fiber. 

 

1.

 

Confirm the fiber is 
in good condition. 

2.

 

Enter the menu to 
check parameter 
setting and set the 
proper parameter. 

3.

 

Do art test until 
current is proper. 
Reload fiber, press 
“RUN” to check the 
fusion. 
If it doesn’t work, 
contact us. 

14) Normal splicing. 
But the value of fusion 
loss is too large and 
fusion is failing. 

1.

 

Check whether 
there is fault in 
system or there is 
dust on the lens or 
lights or reflector. 

2.

 

The value of 
“Setting end-face” 
is too large. 

3.

 

Open the 
windshield before 
the test.   

1.Wipe the lens, 
reflector and two lights; 
decrease the parameter 
of “Setting end-face”. 
2.Do arc test until the 
current is proper, and 
then slice the fiber. 
If it doesn’t work, 
contact us. 

All problems are 
caused by inner 
circuit fault 
probably. 
If you couldn’t   
solve the 
problems, 
please sent it   
to us with 
detailed 
explanation. 

15) There is bubble on 
the spliced fiber or the 
fiber becomes coarse or 
tenuous.   

1.

 

The end-face of 
fiber is unqualified 
or there is dust on 
it. 

2.

 

The setting of 
program parameter 
is wrong. 

Make sure that the end-
face is good. 
Test current until it is 
proper then try again. 
If it doesn’t work, 
change the value of 
“Pre-fusion current, 
time” or    “Fusion 
push” 

16) The splicing index is 
too large.   
(actual measure) 

1.

 

There is dust in V-
groove, 

2.

 

Improper current 

3.

 

The fiber is not 
aligned. 

4.

 

The electrode 
doesn’t work well. 

5.

 

Improper setting 
of program 
parameter. 

6.

 

Unqualified end-
face. The cleaver 
is not good. 

7.

 

Special fiber. 

8.

 

Bad environment. 

1.Clean the V-groove, 
lens or electrode. 
2.Select proper program 
to arc. 
3.Adjust the cleaver. 
4.If the splicing index is 
too large, change the 
value of “Pre-fusion 
current” or “Fusion 
push”, find proper 
program. 
5.Make sure that the 
wind power is proper.   

Содержание FSP-100

Страница 1: ...www youfibercable com FSP 100 Ningbo Youxin Optic Electronic Technology Co LTD Optical Fiber Fusion Splicer User Manual...

Страница 2: ...has strictly limitation to the power supply module used 5 The fusion splicer is prohibited to be used under the environment with the inflammable liquid or flammable gas otherwise will lead to fire ex...

Страница 3: ...Making fiber s end face 6 2 4 Side elevation of cleaved fiber s end face 6 3 Fusion 6 3 1 Selecting proper fusion program 6 3 2 Loading fiber 6 3 3 Fusion instance and measure 6 3 4 Auto fusion and es...

Страница 4: ...s arc parameter 8 4 2 Optimization of MM fiber s arc parameter 9 Setting working mode and parameter 9 1 Setting working mode 9 2 Setting working parameter 10 Maintenance 10 1 Replacing electrode 10 2...

Страница 5: ...de silex fiber 125 m outer diameter standard 0 2 1 5mm outer coating diameter Fiber cleaved length 16mm standard 1 2 Specifications Screen 5 inches color LCD Monitor Display Display X and Y axis simul...

Страница 6: ...r adjusts the warp between left and right fiber to make them are collinear during splicing Test fusion splicer arcs to revise arc position and arc current automatically Cleaning electrode Part high te...

Страница 7: ...able com MSN youfiber hotmail com 7 4 Panel and side elevation Figure 1 The sketch map of main body s panel v Figure 2 Side View of Main Body LCD Monitor Heat Oven Windshield Keyboard P S Modules P S...

Страница 8: ...ove cursor Scroll right Invalid Add parameter or move cursor Scroll up Invalid Add parameter or move cursor Scroll down Invalid Low parameter or move cursor FUNCTION Shift left right fiber driving Inv...

Страница 9: ...then start machine initialize the fusion splicer 3 Observe arc electrodes make sure that no obvious damage on electrode s top 4 Close wind shield 5 Arc to check state of electrode s top as following...

Страница 10: ...flatly and the inclination between end surface and section should be less than 1 The figure5 a is finer end surface for fusion while b f are unqualified and need to remade 1 a the good end face b the...

Страница 11: ...ber over again and clean V groove Consult 10 4 2R LCD monitor R Figure 6 fiber of X axis and Y axis 6 3 3 Fusion instance and measure Table 2 is the possible phenomena that appeared after pressing RUN...

Страница 12: ...ure are unclear in two directions 1 There is dust in V groove 2 There is dust on bare fiber 1 Clean V groove 2 Clean bare fiber 3 Reload fiber 6 3 4 Auto fusion and estimating loss The steps of auto f...

Страница 13: ...er the parameter is proper 2 If opposite position is steady and the parameter is proper maybe fiber s core is partial The solution is minish the value of fusion time and fusion push 3 If method 2 is u...

Страница 14: ...d this function when you enter into MENU please open this function and after each splicing machine will do tension test After you start the machine the screen displays as left picture 6 5 Protection o...

Страница 15: ...ot 7 Explanation about menu The most function and parameter are achieved in the menu the operation methods are as follows Press MENU to enter the first class menu as right picture Cursor point to the...

Страница 16: ...lect 20 kinds different fusion program SMF 100 MMF 100 7 4 1 Splicing fiber Figure 1 stands for selecting SM fiber and figure 2 stands for selecting MM fiber 7 4 2 Fusion program It stands for the ado...

Страница 17: ...point to Maintenance press ENT to enter maintenance menu It contains daily maintenance and part accessorial content as right picture Cursor stands for current selection Press or to move cursor Press...

Страница 18: ...lecting fusion program Fusion Splicer provides function to correct arc current automatically to satisfy different requirement you can select different fusion parameters The operations are as follows 1...

Страница 19: ...nt 14 If Too large fusion current or Too small fusion current is displayed on the screen please repeat step 10 13 until Right fusion current is displayed So test is finished and arc program will be re...

Страница 20: ...inciples of optimization of arc parameter when splicing MM fiber 1 The value of Pre fusion current mustn t be bigger than the value of Fusion current 2 The value of Pre fusion time must bigger than sp...

Страница 21: ...fibers Usually do not adjust electrode and to avoid damage of electrode do not touch the electrode s top in the whole process prevent electrode dropping into the machine After replacing electrode you...

Страница 22: ...vel if any things exists You should clean the V groove timely as following operations 1 Open the windshield 2 Open the fiber holder and fiber clamp 3 Using the special tool to push several times at th...

Страница 23: ...resolve some questions by yourself 1 The screen is dark after starting machine Solutions 1 Check whether the electrical outlet is inserted 2 Check whether the voltage of P S is too low 3 Check electri...

Страница 24: ...ace is too small if you want to keep on working you can increase it 3 After Bad left fiber s surface is displayed the screen becomes dark Make sure that windshield is covered well Raise windshield che...

Страница 25: ...lows 1 Enter the menu of arc parameter 2 Increase 1 step size 10m s to the value of Pre fusion time 3 Splice fiber increase the value of Pre fusion time until no bubble 4 Decrease the value of Pre fus...

Страница 26: ...ther there is something in the machine then restart If it doesn t work please contact us All problems are caused by inner circuit fault probably If you couldn t solve the problems please sent it to us...

Страница 27: ...All problems are caused by inner circuit fault probably If you couldn t solve the problems please sent it to us with detailed explanation 7 Always display bad fiber end face of one side 1 The value of...

Страница 28: ...board push the groove toward to near V groove check whether the two grooves lie in same line and same flat then manage it 2 Reload fiber 3 If it doesn t work contact us All problems are caused by inne...

Страница 29: ...d face 2 Do arc test until the current is proper and then slice the fiber If it doesn t work contact us All problems are caused by inner circuit fault probably If you couldn t solve the problems pleas...

Страница 30: ...pressed by mistake 1 Don t press HEAT when pressing the RUN and the machine is in mode of auto splice 2 Don t press HEAT when pressing TEST and the machine is in arc test 15 Addenda E Introduction of...

Страница 31: ...e battery in low environment to avoid reduce the working life D Taking down the battery is prohibited E Battery is expendable please replace it with the type of battery appointed by our company when t...

Страница 32: ...ion Ningbo Youxin Optic Electronic Technology Co LIMITED Address 527 528 95 International Plaza 598 Jiangnan Road Hi Tech Zone Ningbo Zhejiang China Tel 86 574 89118312 86 574 89118313 86 574 89118317...

Отзывы: