The heating processes are as follows:
1>
Open heater and put the splice protection sleeve into it.
2>
Press “HEAT” to heat splice protection sleeve when light is on.
3>
After time is up, the light will stop heating automatically.
4>
Wait a moment, after splice protection sleeve stiffen, take out it and the joint
protection is finished.
Figure 7(a) and 8(b) are the good examples; 8(c) is the bad example. If the phenomenon as 8(c)
appears you should remake the joint and check whether there is dust in the splice protection sleeve and
on bare fiber, then heat it.
splice protection sleeve bare fiber covered fiber
(a)
(c)
bad example, have bubbles
(b)
good example, no bubbles
Notice: Please do not press “HEAT” after you press “RUN ” to avoid error.
To avoid damage the heating groove, please do not press it with hard thing whatever heater is in
work condition or not.
7
Explanation about menu
The most function and parameter are achieved in the menu; the operation methods
are as follows:
Press “MENU” to enter the first class menu as right picture.
Cursor “
→
”
point to the optional or modifiable content,
press “▲” or “▼” to move the cursor; The next line’s number
is value of the item, press “◄” or “►” to modify;
The modification quantity in the bottom of menu stands for the
change quantity of increase/decrease key when modify certain
value, you can press “AUTO” to select among “1,10,100”;
Press “ENT” to confirm or enter next menu; Press “MENU” to
exit current menu.
Remark: You must press “ENT” to confirm after modifying the value.
Item
Content
Heat time
Setup heat time of heater on the panel
Setting end-surface
The maximum cleaved angle when it works
Tension Test
Setting whether test tension after splicing finish
Current deflection
Basic value of arc current (do not change it)
Fusion program
Different fusion program (200 kinds)
Fusion fiber
SM fiber or MM fiber optionally
08-10-10 15:30
HEATING TIME (1S)
30
CLEAVE ANGLE (0.5
.
)
5
PROOF ENABLE(1ON/2OFF)
2
PROGRAME (1-100)
6
FIBER (1SM, 2MM)
1
SPLICE SELECT (1A, 2M)
1
MAINTENANCE