5167821-YTG-K-1118
Johnson Controls Ducted Systems
35
115°F
125°F
750
77
29.3
2.2
12.1
6.8
5.8
-
-
-
27.3
2.5
11.2
5.5
4.6
-
-
-
72
24.3
2.2
15.7
12.7
9.6
6.6
-
-
22.0
2.5
13.9
11.1
8.2
5.4
-
-
67
19.3
2.3
19.3
18.5
13.5
10.5
7.5
-
16.7
2.6
16.7
16.7
11.8
8.9
6.1
-
62
17.1
2.3
17.1
17.1
12.7
9.7
6.6
3.6
15.3
2.5
15.3
15.3
11.0
8.2
5.3
2.5
900
77
29.3
2.2
16.8
10.1
6.4
-
-
-
27.1
2.5
15.7
8.8
5.2
-
-
-
72 24.3
2.2
18.1
14.4
10.7
7.1
-
-
21.8
2.5
16.1
12.7
9.2
5.7
-
-
67 19.3
2.3
19.3
18.7
15.1
11.4
7.7
-
16.5
2.6
16.5
16.5
13.2
9.7
6.2
-
62 17.1
2.3
17.1
17.1
14.2
10.5
6.8
3.2
15.2
2.5
15.2
15.2
12.3
8.9
5.4
1.9
57 16.4
2.3
16.4
16.4
13.5
9.9
6.2
2.5
13.1
2.5
13.1
13.1
10.6
7.1
3.6
0.2
1050
77 29.3
2.2
21.6
13.3
7.1
-
-
-
26.9
2.5
20.3
12.1
5.7
-
-
-
72 24.3
2.2
20.5
16.2
11.9
7.6
-
-
21.7
2.5
18.4
14.3
10.2
6.1
-
-
67 19.3
2.3
19.3
19.0
16.6
12.3
8.0
-
16.4
2.6
16.4
16.4
14.6
10.5
6.4
-
62 17.1
2.3
17.1
17.1
15.6
11.3
7.0
2.7
15.1
2.6
15.1
15.1
13.6
9.5
5.4
1.3
57 16.4
2.3
16.4
16.4
14.9
10.6
6.3
2.0
13.0
2.6
13.0
13.0
11.7
7.6
3.5
-0.6
1200
77 29.3
2.2
26.4
16.6
7.8
-
-
-
26.7
2.5
24.9
15.5
6.3
-
-
-
72 24.3
2.2
22.9
17.9
13.0
8.1
-
-
21.5
2.5
20.6
15.9
11.1
6.4
-
-
67 19.3
2.3
19.3
19.3
18.2
13.3
8.3
-
16.3
2.6
16.3
16.3
16.0
11.3
6.5
-
62 17.1
2.3
17.1
17.1
17.1
12.2
7.2
2.3
14.9
2.6
14.9
14.9
14.9
10.2
5.5
0.8
57 16.4
2.3
16.4
16.4
16.4
11.4
6.5
1.5
12.9
2.6
12.9
12.9
12.9
8.1
3.4
-1.3
1350
72 24.7
2.2
24.0
19.2
13.6
8.0
-
-
22.0
2.5
21.5
16.9
11.5
6.1
-
-
67 19.6
2.3
19.6
19.6
19.1
13.5
7.9
-
16.7
2.6
16.7
16.7
16.5
11.1
5.8
-
62 17.4
2.3
17.4
17.4
17.4
11.8
6.2
0.6
15.3
2.6
15.3
15.3
15.3
9.9
4.6
-0.8
57 16.7
2.3
16.7
16.7
16.7
11.1
5.5
-0.1
13.2
2.6
13.2
13.2
13.2
7.8
2.4
-2.9
1500
72 25.2
2.2
25.2
20.5
14.3
8.0
-
-
22.5
2.5
22.5
17.9
11.9
5.8
-
-
67 20.0
2.3
20.0
20.0
20.0
13.7
7.5
-
17.0
2.6
17.0
17.0
17.0
11.0
5.0
-
62 17.7
2.3
17.7
17.7
17.7
11.5
5.2
-1.0
15.6
2.6
15.6
15.6
15.6
9.6
3.6
-2.4
57 17.0
2.3
17.0
17.0
17.0
10.7
4.4
-1.8
13.5
2.6
13.5
13.5
13.5
7.5
1.5
-4.5
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT078 (6.5 ton) 1st stage cooling (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F)
Return dry bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65