5167821-YTG-K-1118
Johnson Controls Ducted Systems
61
115°F
125°F
2250
77
105.9
8.9
44.6
40.1
29.6
-
-
-
95.6
10.1
42.3
35.8
26.2
-
-
-
72
97.1
9.0
64.9
54.4
44.0
33.5
-
-
87.6
10.2
61.0
50.6
40.2
29.8
-
-
67
88.3
9.1
85.2
68.8
58.3
47.8
37.4
-
79.6
10.3
79.6
64.6
54.2
43.8
33.4
-
62
84.6
9.2
84.6
82.0
66.2
55.7
45.2
34.8
77.5
10.3
77.5
74.9
59.2
48.8
38.5
28.1
2700
77
108.9
8.9
57.1
44.9
32.7
-
-
-
98.4
10.1
56.0
41.3
29.2
-
-
-
72 99.8
9.0
72.9
60.7
48.5
36.3
-
-
90.1
10.2
68.9
56.8
44.7
32.6
-
-
67 90.8
9.1
88.8
76.6
64.4
52.2
40.0
-
81.9
10.3
81.9
72.4
60.2
48.1
36.0
-
62 87.0
9.2
87.0
85.2
73.0
60.8
48.7
36.5
79.7
10.3
79.7
78.0
65.9
53.7
41.6
29.5
57 87.4
9.2
87.4
85.2
73.0
60.8
48.6
36.4
80.0
10.4
80.0
77.8
65.7
53.6
41.4
29.3
3150
77 111.9
9.0
69.5
49.7
35.8
-
-
-
101.1
10.1
69.7
46.7
32.1
-
-
-
72 102.6
9.0
80.9
67.0
53.1
39.2
-
-
92.6
10.2
76.9
63.1
49.2
35.3
-
-
67 93.3
9.1
92.3
84.3
70.4
56.5
42.6
-
84.2
10.3
84.2
80.1
66.3
52.4
38.5
-
62 89.4
9.2
89.4
88.5
79.9
66.0
52.1
38.2
81.9
10.3
81.9
81.1
72.5
58.6
44.8
30.9
57 89.8
9.2
89.8
88.7
79.8
65.9
52.0
38.1
82.3
10.4
82.3
81.1
72.3
58.4
44.6
30.7
3600
77 114.9
9.0
82.0
54.5
38.8
-
-
-
103.8
10.2
83.4
52.1
35.0
-
-
-
72 105.4
9.0
88.9
73.3
57.6
42.0
-
-
95.1
10.2
84.9
69.3
53.7
38.1
-
-
67 95.8
9.1
95.8
92.1
76.4
60.8
45.2
-
86.5
10.3
86.5
86.5
72.3
56.7
41.1
-
62 91.8
9.2
91.8
91.8
86.8
71.1
55.5
39.9
84.2
10.4
84.2
84.2
79.2
63.5
47.9
32.3
57 92.2
9.2
92.2
92.2
86.7
71.0
55.4
39.8
84.5
10.4
84.5
84.5
78.9
63.3
47.7
32.1
4050
72 106.5
9.0
96.1
78.9
61.8
44.7
-
-
95.8
10.2
91.9
74.8
57.7
40.6
-
-
67 96.8
9.1
96.8
95.0
82.0
64.9
47.8
-
87.0
10.3
87.0
87.0
77.7
60.6
43.5
-
62 92.8
9.1
92.8
92.8
90.3
73.1
56.0
38.9
84.7
10.3
84.7
84.7
82.2
65.1
48.0
30.9
57 93.2
9.2
93.2
93.2
90.4
73.3
56.2
39.1
85.1
10.4
85.1
85.1
82.3
65.2
48.1
31.0
4500
72 107.6
9.0
103.2
84.6
66.0
47.4
-
-
96.4
10.1
96.4
80.3
61.7
43.1
-
-
67 97.8
9.0
97.8
97.8
87.6
69.0
50.4
-
87.6
10.2
87.6
87.6
83.1
64.5
45.9
-
62 93.8
9.1
93.8
93.8
93.8
75.2
56.6
37.9
85.3
10.2
85.3
85.3
85.3
66.7
48.1
29.5
57 94.2
9.1
94.2
94.2
94.2
75.6
57.0
38.4
85.6
10.3
85.6
85.6
85.6
67.0
48.4
29.8
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT150 (12.5 ton) 2nd stage cooling (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F)
Return dry bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65