5167821-YTG-K-1118
Johnson Controls Ducted Systems
51
115°F
125°F
2125
77
107.5
8.1
43.3
38.9
29.2
-
-
-
101.1
8.9
38.8
36.5
26.9
-
-
-
72
97.6
8.0
62.3
52.5
42.8
33.0
-
-
91.5
8.8
59.5
49.8
40.1
30.4
-
-
67
87.8
7.9
81.3
66.1
56.4
46.6
36.8
-
81.9
8.8
80.3
63.0
53.3
43.6
34.0
-
62
79.5
7.9
79.5
79.5
64.0
54.2
44.5
34.7
74.6
8.7
74.6
74.6
58.9
49.2
39.5
29.8
2550
77
109.0
8.1
54.9
43.5
32.1
-
-
-
102.0
8.9
52.5
41.1
29.6
-
-
-
72 99.0
8.0
69.8
58.4
47.0
35.6
-
-
92.3
8.9
67.0
55.6
44.1
32.7
-
-
67 89.1
8.0
84.7
73.3
61.9
50.5
39.1
-
82.6
8.8
81.5
70.1
58.7
47.2
35.8
-
62 80.6
7.9
80.6
80.6
70.3
58.9
47.5
36.1
75.2
8.7
75.2
75.2
64.7
53.3
41.9
30.5
57 82.1
7.9
82.1
82.1
71.6
60.2
48.8
37.4
77.0
8.7
77.0
77.0
66.3
54.8
43.4
32.0
2975
77 110.5
8.1
66.4
48.0
34.9
-
-
-
102.8
9.0
66.2
45.6
32.3
-
-
-
72 100.4
8.1
77.3
64.2
51.2
38.1
-
-
93.0
8.9
74.5
61.3
48.2
35.0
-
-
67 90.3
8.0
88.1
80.5
67.4
54.4
41.3
-
83.2
8.8
82.7
77.1
64.0
50.8
37.7
-
62 81.7
7.9
81.7
81.7
76.6
63.5
50.5
37.4
75.9
8.7
75.9
75.9
70.6
57.5
44.3
31.1
57 83.3
7.9
83.3
83.3
78.0
65.0
51.9
38.9
77.6
8.7
77.6
77.6
72.3
59.1
46.0
32.8
3400
77 112.1
8.1
78.0
52.5
37.8
-
-
-
103.7
9.0
80.0
50.2
35.0
-
-
-
72 101.8
8.1
84.8
70.1
55.4
40.7
-
-
93.8
8.9
81.9
67.0
52.2
37.3
-
-
67 91.6
8.0
91.6
87.7
73.0
58.3
43.6
-
83.9
8.9
83.9
83.9
69.3
54.4
39.5
-
62 82.8
7.9
82.8
82.8
82.8
68.1
53.4
38.7
76.5
8.7
76.5
76.5
76.5
61.6
46.7
31.8
57 84.4
7.9
84.4
84.4
84.4
69.7
55.0
40.3
78.3
8.7
78.3
78.3
78.3
63.4
48.5
33.6
3825
72 102.9
8.1
90.9
75.0
59.0
43.1
-
-
94.2
9.0
87.7
71.6
55.6
39.6
-
-
67 92.5
8.0
92.5
90.6
77.8
61.9
45.9
-
84.3
8.9
84.3
84.3
73.9
57.8
41.8
-
62 83.7
7.9
83.7
83.7
83.7
67.8
51.8
35.9
76.8
8.8
76.8
76.8
76.8
60.8
44.8
28.7
57 85.3
7.9
85.3
85.3
85.3
69.4
53.5
37.5
78.6
8.8
78.6
78.6
78.6
62.6
46.6
30.5
4250
72 103.9
8.1
97.1
79.9
62.7
45.5
-
-
94.7
9.0
93.4
76.2
59.0
41.9
-
-
67 93.5
8.0
93.5
93.5
82.6
65.5
48.3
-
84.7
9.0
84.7
84.7
78.5
61.3
44.1
-
62 84.6
7.9
84.6
84.6
84.6
67.4
50.2
33.1
77.2
8.8
77.2
77.2
77.2
60.0
42.8
25.7
57 86.2
7.9
86.2
86.2
86.2
69.0
51.9
34.7
79.0
8.8
79.0
79.0
79.0
61.8
44.7
27.5
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT102 (8.5 ton) 3rd stage cooling (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F)
Return dry bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65