FORM 150.60-NM3
57
YORK INTERNATIONAL
This message informs the operator whether the Hot Gas
Solenoid is ON or OFF. The micro will activate the Hot
Gas signal regardless of whether or not this option is
installed.
The Run Time for SYS 1 since the last start is displayed.
OFF: Sys 2 Liquid Line Solenoid De-energized
(Closed).
ON: Sys 2 Liquid Line Solenoid Energized (Open).
This message informs the operator of the number of
stages of loading which are active on SYS 2.
This message informs the operator of the number of for-
ward running fans which are active on SYS 2.
This message informs the operator whether the reversing
fan is active on SYS 2.
This message informs the operator whether the Hot Gas
Solenoid is ON or OFF. The Micro will activate the Hot
Gas signal regardless of whether or not this option is
installed.
LOCAL DISPLAY READOUT
Oper Data
The OPER DATA key also allows the user to scroll
through additional real time display information about the
chiller system which is not available from the DISPLAY
keys. This information covers a wide range of data which
includes fan status, loading status, liquid line solenoid
status, run time, etc. A total of 20 different displays are
offered.
When the OPER DATA key is pressed, the following
message will appear:
Repetitively pressing the ENTER key allows the operator
to scroll through the 20 available displays.
In the information that follows, a sample message along
with an explanation of its meaning is provided for all 20
messages.
OFF: SYS 1 Liquid Line Solenoid De-energized
(Closed).
ON: SYS 1 Liquid Line Solenoid Energized (Open).
This message informs the operator of the number of
stages of loading which are active on SYS 1.
This message informs the operator of the number of for-
ward running fans which are active on SYS 1.
This message informs the operator whether the reversing
fan is active on SYS 1.
P R E S S
E N T E R
T O
D I S P L A Y
D A T A
S Y S
1
L I Q U I D
L I N E
S O L E N O I D
S T A T U S
O F F
S Y S
1
S T A G E S
O F
L O A D I N G
2
S Y S
1
F O R W A R D
F A N S
S T A T U S
S Y S
1
R E V E R S E
F A N
S T A T U S
O F F
S Y S
1
H O T
G A S
B Y P A S S
V A L V E
S T A T U S
O F F
S Y S
1
R U N
T I M E
2 0 0
S E C S
S Y S
2
L I Q U I D
L I N E
S O L E N O I D
S T A T U S
O N
S Y S
2
S T A G E S
O F
L O A D I N G
1
S Y S
2
F O R W A R D
F A N S
S T A T U S
O F F
S Y S
2
R E V E R S E
F A N
S T A T U S
O F F
S Y S
2
H O T
G A S
B Y P A S S
V A L V E
S T A T U S
O N
Содержание YCAJ44HE8
Страница 16: ...16 YORK INTERNATIONAL WIRING DIAGRAMS LD02165 FIG 5 ELEMENTARY DIAGRAM...
Страница 17: ...FORM 150 60 NM3 17 YORK INTERNATIONAL FIG 5 ELEMENTARY DIAGRAM Cont d LD02166...
Страница 20: ...20 YORK INTERNATIONAL CONNECTION DIAGRAM ELECTRICAL BOX FIG 7 CONNECTION DIAGRAM LD02171...
Страница 21: ...FORM 150 60 NM3 21 YORK INTERNATIONAL FIG 7 CONNECTION DIAGRAM Cont d LD02172...