8-4
IM WT310E-17EN
INTEGrate Group
Function
WT210/WT230 Command
Command of This Instrument
Command Mode: WT200
Command Mode: WT300, WT300E
Sets or queries the integration
mode.
:INTEGrate:MODE
A
A
Resets the integrated value.
:INTEGrate:RESet
A
A
Starts integration.
:INTEGrate:STARt
A
A
Stops integration.
:INTEGrate:STOP
A
A
Sets or queries the integration
timer value.
:INTEGrate:TIMer
B
Cannot be set with a string.
B
Cannot be set with a string.
MATH Group
Function
WT210/WT230 Command
Command of This Instrument
Command Mode: WT200
Command Mode: WT300, WT300E
Sets or queries the equation of
four arithmetic operations.
:MATH:ARIThmetic
A
D
:MATH
{EFFiciency|CFU<x>|CFI
<x>|ADD|SUB|MUL|DIV|DIVA|
DIVB|AVW<x>}
EFFiciency: Efficiency
CFU<x>,CFI<x> :
Voltage and current crest
factor<x> = 1 to 3 (element)
AVW<x> :
Average active power during
integration
<x> = 1 to 3 (element), 4 (Σ)
Sets or queries the average
active power computation
while integration is in progress.
:MATH:AVERage
A
D
Sets or queries the crest factor
equation.
:MATH:CFACtor
A
D
Sets or queries the
computation type.
:MATH:TYPE
A
D
MEASure Group
Function
WT210/WT230 Command
Command of This Instrument
Command Mode: WT200
Command Mode: WT300, WT300E
Queries all harmonic
measurement data settings.
:MEASure:HARMonics?
A
D
:NUMeric:LIST?
Queries all settings related
to the communication
output items of harmonic
measurement data.
:MEASure:HARMonics:ITEM?
A
D
:NUMeric:LIST:ITEM<x>
Sets the communication output
on/off states of all harmonic
measurement functions to a
preset pattern at once.
:MEASure:HARMonics:ITEM:
PRESet
A
D
:NUMeric:LIST:PRESet
Sets or queries the
communication output
on/off state of a harmonic
measurement function.
:MEASure:HARMonics:
ITEM:{<harmonic measurement
function>|SYNChronize}
A
D
:NUMeric:LIST:ITEM<x>
Queries the harmonic
measurement data that has
been set with commands
that start with “MEASure:
HARMonics:ITEM.”
:MEASure:HARMonics:VALue?
:MEASure:HARMonics:BINary?
A
D
(1) :NUMeric:FORMat
{ASCii|FLOat}
(2) :NUMeric:LIST:VALue?
Sets or queries the additional
information output on/off state
for when outputting measured/
computed data in binary
format.
:MEASure:HEADer
C
Setting and querying
are possible, but setting
this command to ON
will not cause additional
information to be output.
D
Queries all normal
measurement data settings.
:MEASure:NORMal?
A
D
:NUMeric:NORMal?
Queries all settings related
to the communication output
items of normal measurement
data.
:MEASure[:NORMal]:ITEM?
A
D
:NUMeric:NORMal?
Sets the communication output
on/off states of all normal
measurement functions to a
preset pattern at once.
:MEASure[:NORMal]:ITEM:
PRESet
A
D
:NUMeric[:NORMal]:PRESet
8.1 WT210/WT230 Compatible Mode