8-4
IM 05P07A01-01EN
Classification of D Registers
Register No.
Area and data categories
Description
Reference
D0001 to D0049
Configuration map for GREEN Series
(See 8.6 GREEN Series Compatible D
Registers)
Process data
Sections 8.6.3
D0050 to D0100
User area
Sections 8.6.3
D0101 to D0200
Program setting parameter (for UP35A only) Sections 8.6.3
D0201 to D0230
Operation mode parameter
Sections 8.6.4
D0231 to D0300
Operation-related parameter
Sections 8.6.4
D0301 to D0500
PID parameter
Sections 8.6.5
D0501 to D0900
Free area
D0901 to D1000
Control action parameter
Sections 8.6.6
D1001 to D1100
Common function parameter
Sections 8.6.7
D1101 to D1200
Display and I/O configuration parameter
Sections 8.6.8
D1201 to D1300
Controller mode, PV input, and control output parameter
Sections 8.6.9
D1301 to D2000
Free area
D2001 to D2100
Process monitoring
Process data
Sections 8.4.1
D2101 to D2200
Current SP group and PID group
D2201 to D2300
Program pattern parameter (for
UP35A only)
Local-mode operation setting
D2301 to D2400
Operation mode parameter,
Operation parameter (for UP35A/
UT32A only)
Operation mode,
Alarm setpoint setting (for UP35A only)
Sections 8.4.2
D2401 to D2500
Free area
D2501 to D2700
Operation parameter
SP and alarm setpoint setting (for UT35A/UT32A only)
Sections 8.4.3
D2701 to D2800
SP-related setting
D2801 to D2900
Alarm function setting
D2901 to D3000
PV-related setting
D3001 to D3500
PID setting
D3501 to D3600
Control action-related setting
D3601 to D3700
Loop-2 operation parameter
(for UT32A-D only)
SP and alarm setpoint setting (for UT35A/UT32A/
UT32A-D only)
Sections 8.4.4
D3701 to D3800
SP-related setting
D3801 to D3900
Alarm function setting
D3901 to D4000
PV-related setting
D4101 to D4600
PID setting
D4601 to D4700
Control action-related setting
D3601 to D4700
Free area
Free area
D4701 to D4800
P parameter
P parameter
Sections 8.4.5
D4801 to D5000
Free area
Free area
D5001 to D5100
Setup parameter
Control function setting
Sections 8.4.6
D5101 to D5300
Input setting
D5301 to D5400
Output setting
D5401 to D5500
Heater break alarm setting
D5501 to D5700
Communication setting
D5701 to D5800
Key action setting / Display function setting /
SELECT display setting
D5801 to D5900
Lock setting (Key lock / menu lock)
D5901 to D6200
DI function setting
D6201 to D6300
DO function setting
D6301 to D6400
I/O display
D6401 to D6500
System setting
D6501 to D6700
Free area
D6701 to D6800
P parameter
P parameter
Sections 8.4.7
D6801 to D7000
Free area
Free area
D7001 to D7100
Registers for ladder program
For
input ladder calculation
Sections 8.4.8
D7101 to D7200
For output ladder calculation
D7201 to D7300
Status register
D7301 to D7500
Constant register
D7501 to D7600
Input range / scale
D7601 to D7700
Terminal status register
Input / Output terminal status register
Sections 8.4.9
D8001 to D8100
Program pattern parameter (for
UP35A/UT32A only)
Pattern data setting
Sections 8.4.10
D8101 to D8200
Segment data setting
D8201 to D8600
Final target setpoint setting for batch writing
D8601 to D9000
Segment time setting / Segment ramp-rate setting for batch writing
8.3 Classification of D Registers
Содержание UTAdvanced Series
Страница 17: ...Blank Page...
Страница 77: ...Blank Page...
Страница 285: ...Blank Page...
Страница 325: ...Blank Page...
Страница 467: ...Blank Page...
Страница 557: ...Blank Page...
Страница 825: ...Blank Page...
Страница 861: ...Blank Page...
Страница 863: ...Blank Page...
Страница 865: ...Blank Page...