1-9

TI 04L55B01-01EN

 Vehicles

l

  Car air conditioner evaluation

•  The GM is used to acquire in-car temperatures, duct temperatures and humidities, supplied 

voltages, outside air temperatures, engine on/off state, and other types of data.

•  The wide operating temperature range of -20 to 60°C enables testing in environmental test 

labs, hot and cold regions, and so on.

•  Monitoring on a tablet is possible with the Bluetooth (/C8) option.

Temperature

Tablet

Bluetooth

Inside a car

Humidity

l

  Engine durability testing

•  The GM acquires various types of data, such as air temperature, water temperature, 

rotation, air volume, exhaust gas, in tests performed on engine test benches. Long-term 

data acquisition is possible such as in durability tests performed by supplying rotation and 

load control signals and varying the measurement conditions.

•  Data acquisition is possible at different time intervals for each bench (multi-logging, (/BT 

option)) by using the Data Logging Software GA10.

GA10

Multilogging

Bench 1

Bench 2

Bench 3

Block temperature

Water temperature

Oil temperature

Rotation

Air volume

Exhaust gas 

concentration

Main unit

Sub unit

Ethernet

Bench 1

Bench 2

Bench 3

Test start

Test stop

1

What Is S GM?

Содержание SMARTDAC+ GM

Страница 1: ...Technical Information Data Acquisition System Introduction to the Various Features of the GM TI 04L55B01 01EN TI 04L55B01 01EN Copyright Nov 17 2014 4th Edition July 9 2018...

Страница 2: ...Blank Page...

Страница 3: ...3 1 Basic Functions 3 1 3 1 1 Measurement 3 1 3 1 2 Recording 3 7 3 1 3 Output 3 11 3 1 4 Storage 3 12 3 1 5 Display Web browser 3 13 3 2 Various Functions 3 15 3 2 1 Alarm Function 3 15 3 2 2 Event A...

Страница 4: ...3 13 Measurement Setting Server Function 3 46 3 3 14 Advanced security function AS option 3 46 3 3 15 Multi batch Function BT option 3 47 3 3 16 AEROSPACE HEAT TREATMENT AH option 3 48 3 3 17 OPC UA S...

Страница 5: ...and functions If you find any inaccuracies or errors in this document please contact Yokogawa Any copy or reproduction of the content of this document in whole or in part without permission is prohib...

Страница 6: ...itions and reductions Measurement on up to 420 channels Easy installation and reduction of modules with slide locks l Easy access from Web browser Hardware configuration Real time monitoring l Mobile...

Страница 7: ...ure the following types of inputs The supported input types vary depending on the module For details on the various input types see section 3 1 1 Measurement Input Type DC voltage DCV Thermocouple TC...

Страница 8: ...V 60mV 0 01 of rdg 5 V 6V 1 5V 0 01 of reading 2 mV TC R S 1 1 C B 1 5 C K 200 0 to 1370 0 C 0 01 of rdg 0 2 C for 0 0 to 1370 0 C 0 15 of rdg 0 2 C for 200 0 to 0 0 C K 200 0 to 500 0 C 0 2 C for 0 0...

Страница 9: ...ent data l Data types Based on the sampled measurement values the GM can recorded two types of measurement data event data and display data the data type depends on the GM settings Measurement data is...

Страница 10: ...tor data over a wide area You do not need to use a dedicated software application PC View on a Web browser Control operation configure Ethernet GM Web screen example n Configuration and Operation You...

Страница 11: ...nd print them You can also calculate statistics on a specified set of data and convert data to ASCII and Excel formats l IP Address Configurator This software is used to set the GM10 s IP address subn...

Страница 12: ...WT Bluetooth Tablet Single unit system Alarm output FAIL status output Manual DO Analog output Remote input Signal input Signal output DO DI Alarm output DI RTD TC DCV mA Pulse A Control input Control...

Страница 13: ...odules Microwave oven Electromagnetic relay scanner Temperature in oven Ambient temperature Sub unit Main unit Noise l Performance evaluation testing of washing machines The GM is used to acquire rota...

Страница 14: ...sting The GM acquires various types of data such as air temperature water temperature rotation air volume exhaust gas in tests performed on engine test benches Long term data acquisition is possible s...

Страница 15: ...hernet Sub unit Main unit Web browser l Air conditioning monitoring in pharmaceutical labs and warehouses The GM is used to acquire and monitor the temperature humidity and the like in storage rooms f...

Страница 16: ...Acquiring and monitoring of process data is easy with Data Logging Software GA10 Temperature Transfer speed Bubbles Photosensitizing agent volume Humidity Ethernet GA10 Film l Temperature distribution...

Страница 17: ...ixed Only one module in a system Power Supply Module GM90PS Power switch Power inlet or terminal M4 A module for supplying power to the unit Supply voltage 100 240 V AC 12 28 V DC Input output Module...

Страница 18: ...sal H0 4 1 ms High speed universal 4 wire RTD resistanse 6 100 ms SSR 4 wire RTD 2 2 Flexible Support for Channel Additions and Reductions YOKOGAWA s original block structure patented l Modules can be...

Страница 19: ...connections can extend up to 100 m total Less wiring is possible by distribution such as when measurement locations are separated far apart Main unit LAN cable Sub unit The main unit and sub units are...

Страница 20: ...b unit When a sub unit is connected Multi unit system Main unit Single unit system Data acquisition module n Sub Unit A sub unit is connected to the main unit An expansion module GX90EX is linked to c...

Страница 21: ...esktop Legs for desktop installation n DIN Rail Mounting The GM can be mounted easily on a DIN rail using the latches on the rear of the module base Latches for DIN rail mounting n Wall Mounting The G...

Страница 22: ...rsal individual A D type H0 4 4 wire RTD resistor scanner type R1 6 Digital input GX90XD 16 Pulse input GX90XP 10 Digital output GX90YD 6 Digital input output GX90WD Input 8 Output 6 Analog output GX9...

Страница 23: ...nto temperature values Input value Measured value 10 V 0 V 300 C 100 C l Delta The measured value of the channel is set to the difference with respect to the measured value of the reference channel Fo...

Страница 24: ...ation Up to 12 correction points can be specified Linearizer approximation Corrects input values using characteristics specified with segments to derive output values Output value Measured value Input...

Страница 25: ...s are present in the system the shortest scan interval that you can set is the shortest scan interval of the slowest module A D conversion Scan interval 1 23 Measured value Input signal Shortest scan...

Страница 26: ...to 16 67 ms Common Sets the integration time to 16 67 ms 20 ms 36 67 ms or 100 ms Integration time and scan interval by module Type Integration Time Scan Interval 10ch mode 2ch mode Universal DC curr...

Страница 27: ...ange Percentage of the specified span width Lower Limit of Burnout 20 0 to 5 0 Upper limit of burnout 105 0 to 120 0 n Operation Modes of Modules l AI modules 2ch mode and 10ch or 6ch mode are availab...

Страница 28: ...ypes Explanation Event data Measurement data that is recorded at the specified recording interval There are two modes One mode starts recording when a trigger occurs The other mode records at all time...

Страница 29: ...ple is not retained but because the maximum and minimum data values are recorded display data expresses the fluctuation range in each recording interval In addition because the number of data values c...

Страница 30: ...The GM enters the trigger wait state when you start recording After a trigger event occurs the GM will record data for the specified time data length and stop From this point the GM will not record ev...

Страница 31: ...y the channels assigned to recording channels are recorded as measurement data You can select the channels to record from AI channels DI channels pulse input channels DO channels math channels MT opti...

Страница 32: ...alarm assigned to a measurement channel occurs a relay signal is output from the DO channel that the alarm output is assigned to Alarm occurrence Relay output l Manual output DO channels can be turne...

Страница 33: ...New l Media FIFO Save Operation Up to the most recent 1000 files are retained If the number of files in the save destination directory exceeds 1000 the number of files is held at 1000 by deleting old...

Страница 34: ...icated software application 3 1 5 Display Web browser Real time monitoring of measurement data is possible from a Web browser You do not need to use a special software application You can also configu...

Страница 35: ...n free messages 1 to 10 Auto message When the GM recovers from a power failure during recording a fixed message is written n Configuration You can configure the GM from a Web browser When a configurat...

Страница 36: ...asured values over a certain interval is greater than or equal to the specified value Change in the measured value Measured value Time Interval t2 t1 T2 T1 t1 t2 Amount of change in the setting T2 T1...

Страница 37: ...l H L T t R r h l Measured value n Hysteresis You can furnish an offset between the value used to activate and release alarms This is fixed at 0 for the DI range Example H If you set the alarm value o...

Страница 38: ...deactivated can be set to 500 ms 1 s or 2 s Relays set to Reflash will operate using OR and Nonhold settings l Energize or De energize Operation You can select whether the alarm output relay is energi...

Страница 39: ...n ACK Relay action on ACK occurrence Activated Deactivated Activated Deactivated Activated Deactivated release Activated Deactivated Display Alarm Hold Non hold DO output relay Hold Non hold Hold Non...

Страница 40: ...ding You can specify this when the GM is configured to event data Message writing Writes a message Specify the message number and the message write destination Set the destination to all groups or spe...

Страница 41: ...elay On Off1 2 Internal Switch2 Internal switch On Off1 2 1 When the operation mode is rising falling edge 2 Action can be set to Relay output Relay On Off Internal switch or Internal switch On Off on...

Страница 42: ...specified loops to manual when the input changes from on to off Remote local switch specified loop Switches the control operation of specified loops to remote when the input changes from off to on Sw...

Страница 43: ...ttern Stops the operation of the specified program pattern of the specified loop when the input changes from on to off Program pattern number switch binary BCD selection Switches the program pattern n...

Страница 44: ...omment l Batch Information Item Explanation Batch No Up to 32 characters A a 1 Lot No Lot numbers can be set to not use 4 digits 6 digits or 8 digits Comments 1 to 3 Up to 50 characters each A a 1 You...

Страница 45: ...Otherwise the result is 0 NE or a NE b or a b The computed result is 1 when a is not equal to b Otherwise the result is 0 Logical operator AND e1ANDe2 If the two data values e1 and e2 are both non zer...

Страница 46: ...itional expression a b c a b c If the value of expression a is true expression b is executed otherwise expression c is executed Remainder extracting operation MOD a MOD b Determines the remainder when...

Страница 47: ...reate a variety of report files from the measured data of I O channels math channels and communication channels You can set up to 60 report channels You can set up to five computation types You can se...

Страница 48: ...y create custom report files Load a report template file that you have created into the GM internal memory The GM will automatically create report files using the report template file Report template...

Страница 49: ...sers administrators and users can log in to the GM to perform monitoring and operation l User Levels User Level Explanation Administrator Admin An administrator can perform all GM operations User Auth...

Страница 50: ...ext field writing Alarm ACK Restricts alarm ACK operations Communication Restricts the operations to start stop and test mail test FTP get and release network information test printer output manually...

Страница 51: ...utput when an error occurs in the internal memory or external storage medium Error in the internal memory Error in the external storage media Measurement error A relay signal is output when a measurem...

Страница 52: ...0 Interval 10 minutes The timer expires at 0 hour 0 hour 10 min 0 hour 20 min 23 hour 40 min and 23 hour 50 min For example if the timer is set at 9 hour 36 min the timer expires at 09 hour 40 min 09...

Страница 53: ...and the decimal digits of the voltage representing the mantissa l Input That Is Linear on a Logarithmic Scale This is referred to as Log linear input Log linear input is input in which the voltage val...

Страница 54: ...ction to correct the GM input values with linear approximation Conceptual diagram The pressure scale is mapped to an input scale that has been multiplied by a constant number to derive the output scal...

Страница 55: ...as retrieving directory and file lists from the external storage medium SD card of the GM and transferring and deleting files In addition you can also retrieve the directory or file list and transfer...

Страница 56: ...created in the external storage medium of the GM can be automatically transferred when they are created Data file FTP server Primary Secondary Ethernet Destination FTP server information Transfer log...

Страница 57: ...cluded is the instantaneous value at the time of the e mail transmission Report Report notification An e mail is transmitted when a report is created Periodic Scheduled notification An e mail is trans...

Страница 58: ...e set on communication channels PC Modbus device WT Communication channel GM10 1 C001 to C300 GM10 2 C001 to C500 Data l Watchdog Timer Function Data may fail to be updated due to Modbus or other comm...

Страница 59: ...annel MC option data Write data to communication channels Start and stop recording write messages and perform other operations Load the recording start stop condition message strings and other types o...

Страница 60: ...ent Ethernet GM Command Input register Hold register Read Write Read 3XXXXX 4XXXXX Write Read Read Server device Winternal register GM l Number of Commands Type Number of Commands GM10 1 100 GM10 2 20...

Страница 61: ...spoofing by other devices and data eavesdropping n Supported Servers HTTP server and FTP server are supported l HTTP Server Function A certificate is saved in the internal memory in advance When a PC...

Страница 62: ...received from the server to the one in the internal memory Encrypted e mail is sent to the server Ethernet Encryption Certificate SMTP server Email Trusted certificate n Trusted Certificate Electroni...

Страница 63: ...format EB Sets the byte output order l ESC T Command If a Esc T command is received time synchronized measured value and math value are held in the local buffer until the next Esc T command is receiv...

Страница 64: ...Starts message printing IM Sets the interrupt mask SM Sets the auxiliary mask l Handling of Commands for Functions Not Available on the GM If a command or parameter for a function not available on the...

Страница 65: ...communications with these PLCs n GM Functions The GM provides the following functions Participate in an EtherNet IP network as an Adapter Server Communicate with new and old Allen Bradley PLCs such as...

Страница 66: ...ORE STORE SET POWER Server 2 Measurement value Computation value l Connectable Models and Options Maker Models Option Description Yokogawa Meter Instrument WT300 WT330 G5 Harmonics Measurement WT500 G...

Страница 67: ...ting Server Function Dedicated commands can be used to configure the GM acquire data and so on Supported interfaces Ethernet USB RS 422 485 C3 Bluetooth C8 3 3 14 Advanced security function AS option...

Страница 68: ...l Main Specifications Item Specification Number of multi batches GM10 1 6 max GM10 2 12 max Batch single operation Memory start stop math reset message writing Batch overview operation Computation sta...

Страница 69: ...and Renotification is set to 8h Notification screen display start Calibration due date Notification screen appears Renotification Renotification Renotification Renotification 00 00 08 00 16 00 00 00...

Страница 70: ...g UA Binary Protocol OPC UATCP Maximum number of connections 3 sessions Profile Micro Embedded Device Server Language English Security Type None Encryption None Login Anonymous Username Data acquisiti...

Страница 71: ...Items SetMonitoringMode Subscription CreateSubscription ModifySubscription DeleteSubscriptions Publish Republish SetPublishingMode l Data Structure Device GM10 1J IP Address or hostname Object IO Chan...

Страница 72: ...e conversion I O channel Math channel Communication channel SLMP Client GX GP Ehernet GM l Communicable internal data Internal data Device code Special relay SM Special register SD Input X Output Y In...

Страница 73: ...uts two control outputs eight digital inputs and eight digital outputs In addition to single loop control cascade control and loop control with PV switching are possible For the control output you can...

Страница 74: ...Add Pulse input module Multi batch function Aerospace heat treatment OPC UA server SLMP communication Mitsubishi PLC June 2017 3rd Edition Supported Release 4 of the Data Acquisition System GM July 20...

Отзывы: