<3. INSTALLATION>
3-3
All Rights Reserved. Copyright © 2003, Rota Yokogawa
IM 01R01B30-00E-E 8th edition November 01, 2019-00
3.2.2 Conductor connection with Quickon
Tab. 3-2 Connections to the Quickon connectors for the respective equipment configuration
Connection
Indicator
Type
Option
Signal
Upper connector 2 (+) 1 (-)
E
Electronic transmitter, 4 to 20 mA supply
Lower connector 1 (+) 2 (-)
E
/CP
Electronic transmitter, pulse output
Lower connector 1 (+) 2 (-)
E
/K1, /K2, /K6, /K7
Single limit switch
Upper connector 1 (+) 2 (-)
T
/K2, /K3, /K7, /K8
Limit switch MAX
Lower connector 1 (+) 2 (-)
T
/K1, /K3, /K6, /K8
Limit switch MIN
Power supply acc. EN 60947-5-6 (Namur)
Power supply
U = 14 to 30 V DC
+ -
R
L
≤ U - 14 V
20 mA
Output 4 to 20 mA
+
-
+
-
Power supply acc. EN 60947-5-6 (Namur) or Fail safe power supply
+
-
L-
L+
F
G
-
P
+
P
Rotameter RAKD
4 to 20 mA
*)
EN 60947-5-6 (Namur)
Pulse output
*)
-
+
BU
BN
Limit switch
*)
2
3
1
3
1
2
4
4
-
+
BU
BN
Limit switch
*)
+
-
Power supply acc. EN 60947-5-6 (Namur) or Fail safe power supply
Alternatively power supply option /UT (4 to 20 mA) or power supply
option /Wxx (pulse output or limit switches) can be used.
M1
M1
M2
M2
M1: upper M12 connector
M2: lower M12 connector
Fig. 3-5 RAKD with M12 connector (option /A29 or /A30), electronic transmitter and limit switches