<7. EXPLOSION-PROTECTED TYPE INSTRUMENTS>
7-25
IM 01R01B30-00E-E 8th edition November 01, 2019-00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
7.13 ATEX non-electrical RAKD (/KC1)
7.13.1 Technical data
Applicable Standards:
EN ISO 80079-36: 2016
Archive No.:
IBExU 137/15
Explosion proof:
II2G Ex h IIC TX Gb
II2D Ex h IIIC TX°C Db
TX = max. surface temperature determined by the process temperature
Ambient temperature:
-25 °C
to
80 °C
Process temperature:
see chapter 7.2
7.13.2 Safety Instructions
Identified hazards:
•
flammable products inside tube
•
static electricity
WARNING
Operation with flammable products is only permitted as long as no explosive mixture builds up on the inside of
the flowmeter under operating conditions. The operator is responsible for ensuring that the flowmeter is operated safely
as regards the temperature and pressure of the products used. In case of operation with flammable
products, the measuring units must be included in the periodic pressure tests of the system.
If conductive fluids are used with metal as material of wetted parts, the Rotameter must be connected to the
potential equalization.
CAUTION
1. Supply grounding connection.
2. In hazardous areas, only operate the indicator with a closed cover.
3. Ignition risks caused by pressure surges, impact or friction must be avoided.
4. Use of the equipment is not permitted in areas where the following occur: processes that generate strong
charges, machine grinding and separation processes, electronic spraying (e.g. near electrostatic painting
systems) or pneumatically conveyed dust.
7.13.3 Marking
Archive No.: IBExU 137/15
II2G Ex h IIC TX Gb
II2D Ex h IIIC TX°C Db
Tamb. -25 °C
...
80 °C