![YOKOGAWA ROTAMETER RAKD Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/yokogawa/rotameter-rakd/rotameter-rakd_user-manual_911338056.webp)
<A1. SAFETY INSTRUMENTED SYSTEMS INSTALLATION>
A1-6
IM 01R01B30-00E-E 8th edition November 01, 2019-00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
Table A1-3: Summary for RAKD ([V1]) with standard limit switches
7
– Failure rates
Profile 3
Fail Safe Detected (
λ
SD)
0 FIT
Fail Safe Undetected (
λ
SU)
81 FIT
Fail Dangerous Detected (
λ
DD)
4 FIT
Fail Dangerous Undetected (
λ
DU)
101 FIT
SFF
4
45 %
MTBF
375 years
SIL AC
5
SIL1
Safety metrics according to ISO 13849-1
6
:
MTTF
d
(years)
1087
DC
4 %
Category (CAT)
CAT 1
Performance Level (required)
PL
r
= c
Performance Level (calculated)
1.05E-07 1/h
T[Proof] = 1 year
T[Proof] = 5 years
T[Proof] = 10 years
PFDAVG = 4.82E-04
PFDAVG = 2.23E-03
PFDAVG = 4.42E-03
Table A1-4: Summary for RAKD ([V2]) with fail-safe limit switches
3
– Failure rates
Profile 3
Fail Safe Detected (
λ
SD)
0 FIT
Fail Safe Undetected (
λ
SU)
51 FIT
Fail Dangerous Detected (
λ
DD)
4 FIT
Fail Dangerous Undetected (
λ
DU)
84 FIT
SFF
4
39 %
MTBF
399 years
SIL AC
5
SIL1
Safety metrics according to ISO 13849-1
6
:
MTTF
d
(years)
1297
DC
5 %
Category (CAT)
CAT 1
Performance Level (required)
PL
r
= c
Performance Level (calculated)
8.80E-08 1/h
T[Proof] = 1 year
T[Proof] = 5 years
T[Proof] = 10 years
PFDAVG = 4.01E-04
PFDAVG = 1.86E-03
PFDAVG = 3.68E-03