<9. TECHNICAL DATA>
9-6
IM 01R01B02-00E-E 12th edition October 01, 2014 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
COMPLIANCE WITH IEC 61508
RAMC with local indicator and fail safe limit switches (-T[]
[]NNN /K6 ... /K10):
Suitable for application in safety functions up to and including
SIL2.
RAMC with local indicator and standard limit switches
(-T[][]NNN /K1 ... /K3):
Suitable for application in safety functions up to and including
SIL2.
RAMC with 4-20mA output (-E[][]424 and -H[][]424):
Suitable for application in safety functions up to and including
SIL1, but only with activated Float Blocking Indication.
Reliability data available on request in FMEDA report.
COMPLIANCE WITH ISO 13849
For Safety Metrics acc. to ISO 13849-2 please refer to the
FMEDA report.
METROLOGICAL REGULATION IN CIS
AND EAC COUNTRIES
Russia, Kazakhstan, Uzbekistan, Ukraine and Belorussia are
members of CIS.
RAMC has “Pattern Approval Certificate of Measuring
Instruments” and is registered as a measuring instrument in
Russia, Kazakhstan, Uzbekistan.
Option /QR1 is for Russia.
Option /QR2 is for Kazakhstan.
Option /QR3 is for Uzbekistan.
For the Ukraine the test certificate of Rota Yokogawa is sufficient.
Therefore no special option exists.
For Belorussia Rota Yokogawa has no “Pattern Approval
Certificate”, that means devices which need primary verification
should be calibrated in Belarus by Belorussian special bod-
ies. Therefore no special option exists.
Russia, Kazakhstan and Belorussia are covered by EAC.
For export to CIS and EAC countries please contact your
Yokogawa representative.
SWITCHING LEVELS FOR LIMIT SWITCHES
Table 2 Min, Max and Min-Max-contact in standard version
Option /K1 Option /K2 Option /K3
Function Pointer
Signal
Signal
Signal
SC3,5-N0
SC3,5-N0
SC3,5-N0
MAX
above LV
below LV
----
----
1 mA
3 mA
1 mA
3 mA
Function Pointer
Signal
Signal
Signal
SC3,5-N0
SC3,5-N0
SC3,5-N0
MIN
above LV
below LV
3 mA
1 mA
----
----
3 mA
1 mA
Note: LV = Limit value
Table 3 Min, Max and Min-Max-contact in fail-safe version
Option /K6 Option /K7 Option /K8
Function Pointer
Signal
Signal
Signal
SJ3,5-SN
SJ3,5-SN
SJ3,5-SN
MAX
above LV
below LV
Fail Safe
----
----
----
1 mA
3 mA
1 mA
1 mA
3 mA
1 mA
Function Pointer
Signal
Signal
Signal
SJ3,5-SN
SJ3,5-SN
SJ3,5-SN
MIN
above LV
below LV
Fail Safe
3 mA
1 mA
1 mA
----
----
----
3 mA
1 mA
1 mA
Note: LV = Limit value
Table 4 Limit switch as Min-Min-contact in fail-safe version
Option /K9
Function Pointer
Signal
SJ3,5-S1N
MIN
above LV
below LV
Fail Safe
3 mA
1 mA
1 mA
Function Pointer
Signal
SJ3,5-SN
MIN
above LV
below LV
Fail Safe
3 mA
1 mA
1 mA
Note: LV = Limit value
Table 5 Limit switch as Max-Max-contact in fail-safe version
Option /K10
Function Pointer
Signal
SJ3,5-SN
MAX
above LV
below LV
Fail Safe
1 mA
3 mA
1 mA
Function Pointer
Signal
SJ3,5-S1N
MAX
above LV
below LV
Fail Safe
1 mA
3 mA
1 mA
Note: LV = Limit value