<Toc> <Ind>
<3. Procedures for Setting PR300 Functions>
3-33
IM 77C01E01-10E
3.7.4
Active Energy Reset
[Procedure]
(1)
To execute active energy reset, write data to the D register in the table below. The
data type is integer.
D Register
D0353
Reference No.
40353
H No.
0160
Description
Active energy
(D0001 and D0002) reset
Effective Range
If other than 1: Invalid
If 1: Active energy reset
[Example]
To execute active energy reset:
For station number 01, use PC link communication (without checksum) and the random
write command as shown below:
[Command]
[STX] 01010WRW01D0353, 0001 [ETX] [CR]
[Response]
[STX] 0101OK [ETX] [CR]
3.7.5
Regenerative Energy Reset
[Procedure]
(1)
To execute regenerative energy reset, write data to the D register in the table below.
The data type is integer.
D Register
D0354
Reference No.
40354
H No.
0161
Description
Regenerative energy
(D0003 and D0004) reset
Effective Range
If other than 1: Invalid
If 1: Regenerative energy
reset
[Example]
To execute regenerative energy reset:
For station number 01, use PC link communication (without checksum) and the random
write command as shown below:
[Command]
[STX] 01010WRW01D0354, 0001 [ETX] [CR]
[Response]
[STX] 0101OK [ETX] [CR]
Содержание PR300