<7. Functions and Usage of D Registers>
7-5
IM 77C01E01-10E
D-Reg
Ref No. H No.
Register Symbol
Register Name
Effective Range
Initial Value BackUp
R/W
No.
D0289
40289
0120
DEFAULT GATEWAY 1
Default gateway-1 (uint 32, 1 byte)
0 to 255
0
䊊
R/W
*
D0290
40290
0121
DEFAULT GATEWAY 2
Default gateway-2 (uint 32, 1 byte)
0 to 255
0
䊊
R/W
*
D0291
40291
0122
DEFAULT GATEWAY 3
Default gateway-3 (uint 32, 1 byte)
0 to 255
0
䊊
R/W
*
D0292
40292
0123
DEFAULT GATEWAY 4
Default gateway-4 (uint 32, 1 byte)
0 to 255
0
䊊
R/W
*
D0293
40293
0124 PORT NUM
Port number
502, 1024 to 65535
502
䊊
R/W
*
If other than 1: Invalid
D0294
40294
0125 ETHERNET STS
Ethernet writing status
If 1: Writing is executed
–
W
(D0281 to D0293 are validated)
D0295 to D0300
D0301
40301
012C
INTEG START STOP
Integration start/stop
0: Stop, 1: Start
1
䊊
R/W
*
D0302
40302 012D Wh START STOP
Optional integration start/stop
0: Stop, 1: Start
0
R/W
*
D0303 to D0310
D0311
40311
0136
DEMAND START STOP Demand measurement start/stop
0: Stop, 1: Start
0
R/W
*
Confirmation and release of
0: Normal state, 1: Alarm state
D0312
40312
0137
DEMAND ALM STATUS
demand alarm state
Writing
“0” during alarm state clears
0
R/W
*
the
alarm.
D0313 to D0350
If other than 1: Invalid
D0351
40351 015E MAX RST
Maximum/minimum values reset
If 1: Maximum/minimum values
–
W
are reset (D0101 to D0138)
If other than 1: Invalid
D0352
40352 015F Wh ALL RST
Energy value all-reset
If 1: All energy values are reset
–
W
(D0001 to D0010)
If other than 1: Invalid
D0353
40353 0160
kWh RST
Active energy reset
If 1: Active energy is reset
–
W
(D0001,
D0002)
If other than 1: Invalid
D0354
40354 0161
RkWh RST
Regenerative energy reset
If 1: Regenerative energy is reset
–
W
(D0003,
D0004)
If other than 1: Invalid
D0355
40355 0162
kVarh RST
Reactive energy reset
If 1: Reactive energy is reset
–
W
(D0005 to D0008)
If other than 1: Invalid
D0356
40356 0163
kVAh RST
Apparent energy reset
If 1: Apparent energy is reset
–
W
(D0009, D0010)
D0357 to D0370
D0371
40371 0172
kWh SET L
Active energy – setpoint (uint 32, lower 2 bytes)
See subsection 3.6.1
–
W
D0372
40372
0173
kWh
SET
H
Active energy – setpoint (uint 32, upper 2 bytes)
If other than 1: Invalid
D0373
40373 0174
kWh STS
Active energy writing status
If 1: The values of D0371 and D0372
–
W
are written as the integrated values.
D0374
40374
0175
RkWh
L
Regenerative
energy
– setpoint
(uint 32, lower 2 bytes)
See subsection 3.6.2
–
W
D0375
40375
0176
RkWh
H
Regenerative
energy
– setpoint
(uint 32, upper 2 bytes)
If other than 1: Invalid
D0376
40376 0177
RkWh STS
Regenerative energy writing status
If 1: The values of D0374 and D0375
–
W
are written as the integrated values.
D0377
40377
0178
Lead kVarh SET L
LEAD
reactive
energy
– setpoint
(uint 32, lower 2 bytes)
See subsection 3.6.3
–
W
D0378
40378
0179
Lead kVarh SET H
LEAD reactive energy – setpoint
(uint 32, upper 2 bytes)
D0379
40379
017A
Lag kVarh SET L
LAG reactive energy – setpoint
(uint 32, lower 2 bytes)
See subsection 3.6.4
–
W
D0380
40380
017B
Lag kVarh SET H
LAG reactive energy – setpoint
(uint 32, upper 2 bytes)
If other than 1: Invalid
D0381
40381 017C kVarh STS
Reactive energy writing status
If 1: The values of D0377 to D0380
–
W
are written as the integrated values.
D0382
40382 017D kVAh SET L
Apparent energy – setpoint
(uint 32, lower 2 bytes)
See subsection 3.6.5
–
W
D0383
40383 017E kVAh SET H
Apparent energy – setpoint
(uint 32, upper 2 bytes)
If other than 1: Invalid
D0384
40384 017F kVAh STS
Apparent energy writing status
If 1: The values of D0382 and D0383
–
W
are written as the integrated values.
D0385 to D0399
If other than 1: Invalid
D0400
40400 018F RMT RST
Remote reset
If 1: PR300 is reset (the same effect
0
W
as turning the power off and then on)
* D register with a blank cannot be used. (Writing to this area is not guaranteed.)