<13. General Specifications>
13-5
IM 01S01C01-01EN
13.6 Dimensions
Electrical connection for code 5, 9, A and D
54
(2.13)
6
(0.24)
12
(0.47)
2-inch pipe
(O.D. 60.5 mm)
Mounting bracket
(optional)
126 (4.96)
139 (5.47)
159 (6.26)
Conduit connection
Conduit connection
95 (3.74)
*1
60
(2.36)
50
(1.97)
Scroll knob
188 (7.40)
110 (4.33)
12
(0.47)
39
(1.54)
129 (5.08)
110 (4.33)
Ø70 (2.76)
Ø78 (3.07)
F1302.ai
Unit: mm (approx.inch)
Ground
terminal
Body
*1: When electrical connection code 7 or C is selected, a blind plug is protruded upto 8 mm from the conduit connection.
F1303.ai
–
Power supply and output terminals
Ground terminal
1
2
1
Terminal
2
Terminal
● Terminal Configuration
● Terminal Wiring
<Factory Setting>
Tag Number
(Tag plate)
As specified in order
Software Tag
(PD_TAG)
'UI1001' unless otherwise both Tag
Number
and software Tag specified in order
Node Address
'0xF5' unless otherwise specified in
order
Operation
Functional
Class
BASIC or as specified