10.1 Selecting Adjustment of Dot-Printing Position or
Scan Interval
D I S P
M O D E
P R I N T
F U N C
I N S
D E L
R A N G E A L A R M
S E T
C H A R T
E N T E R
F E E D
M. F U N C 1
M. F U N C 2
RECORD
ALARM
CHART
KEYLOCK
R E C O R D
SETUP=PRN_ADJ
PRN_ADJ SCAN_INTVL RECORD ALARM A/D_IN
↑
>Select Setting Parameter
E S C
• Enter the SET UP menu in the following procedure:
1. When the display presents the operation display mode or a menu other than the SET UP
menu, first turn off the power switch.
2. Turn the switch back on while pressing the DISP key and continue pressing the DISP key
for about 5 seconds.
• Select/set
using the
keys.
• To escape from a lower menu, press the MODE (ESC) key. Its main menu will appear,
although new settings/selections will not be kept.
• New settings/selections will be kept when you reach the final display of that setting.
SET UP=
PRN ADJ
SCAN INTVL
PRINTER HYS=–_ _ _2
>Hys Limit(– 50~ 50)
PRINTER ZERO=_ _326
>Zero Limit (1~500)
PRINTER FULL=_2506
>Full Limit (2400~2600)*
***PRINTER SET***
SCAN INTERVAL=2
(sec)
2 3 4 5 6 10 12 15 20 30 60
***SCAN INTVL SET***
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ESC
ESC
( M a i n m e n u )
( L o w e r m e n u )
*: For the DR130, indicated as "Full Limit (1400-1600)."