<1. Outline>
1-4
IM 11R02A01-02E
6th Edition :May 10, 2019-00
• Orifice Assembly
Name
Q’ty
Remarks
O-Ring
O-Ring
Hexagon Wrench
Hexagon Wrench
1
3
1
1
P16 (Viton) (Y9114XB)
P20 (Silicon) (L9817MT)
Nominal size 1.5 mm
Nominal size 2.5 mm
n
Gas Density Meter
Gas Density Meter compensates a density value in calorific value measurement.
It is not required for WI measurement.
Converter: GD400G-N-10-N-
/PA
Detector: GD300S-J-
/KU
Measuring range and unit (specific gravity or density) should be specified. See GS 11T3E1-01E
for further information.
n
Option
You must purchase options separately.
Name
Part no.
Description
Probe
H7800HA
Insertion length 650 mm
Probe
H7800HB
Insertion length 1150 mm
Probe
H7800HC
Insertion length 1650 mm
Fulflo filter
G7043XJ
Element material: Polypropylene
Pore size: 50 μm
Body: SUS 316
Connection: Rc 1/2
Pressure reducing valve
G7008XF
Primary pressure: 15 MPa max.
Secondary pressure: 0 to 200 kPa
Material: Brass
1.3
Standard Systems for Each Application
Application Measurement
System specification
Suffix code*
Town Gas
WI
Without
density
meter
Gas pressure 10 to 20 kPa: Standard
Gas pressure 10 kPa or under: With pump
Gas pressure 100 to 600 kPa: With pressure
reducing value
-S6200
-S6300
-S6400
Calorific value
MJ/Nm
3
With
density
meter
Gas pressure 10 to 20 kPa: Quake-proof
Gas pressure 10 to 20 kPa: Standard
Gas pressure 10 kPa or under: With pump
Gas pressure 100 to 600 kPa: With pressure
reducing value
-S6110
-S6210
-S6310
-S6410
Steel Mill
WI
Without
density
meter
Gas pressure 8 to 15 kPa: Without preheating
Gas pressure 8 to 15 kPa: With preheating
Gas pressure 8 kPa or under: Without preheating
Gas pressure 8 kPa or under: With preheating
-S6500
-S6600
-S6700
-S6800
Calorific value
MJ/Nm
3
With
density
meter
Gas pressure 8 to 15 kPa: Without preheating
Gas pressure 8 to 15 kPa: With preheating
Gas pressure 8 kPa or under: Without preheating
Gas pressure 8 kPa or under: With preheating
-S6510
-S6610
-S6710
-S6810
*
The code is basic for gas pressure and measurement.
Note: A wet sample gas in the town gas application is outside the scope of the standard specifications. Consult
with Yokogawa.