Order no.
M13-CCF0000
Lamp load
10 W
Parallel switching of outputs for redundant control of a load not possible
Parallel switching of outputs for increased power
not possible
Actuation of digital input
ü
Switching frequency with resistive load
max. 1000 Hz
Switching frequency with inductive load
max. 0.5 Hz
Switching frequency on lamp load
max. 10 Hz
Internal limitation of inductive shut-off voltage
L+ (-45 V)
Short-circuit protection of output
yes, electronic
Trigger level
1 A
Number of operating cycle of relay outputs
-
Switching capacity of contacts
-
Output data size
12 Bit
Technical data analog inputs
Number of inputs
2
Cable length, shielded
200 m
Rated load voltage
-
Reverse polarity protection of rated load voltage
-
Current consumption from load voltage L+ (without load)
-
Voltage inputs
ü
Min. input resistance (voltage range)
100 kΩ
Input voltage ranges
0 V ... +10 V
Operational limit of voltage ranges
+/-3.5%
Operational limit of voltage ranges with SFU
-
Basic error limit voltage ranges
+/-3.0%
Basic error limit voltage ranges with SFU
-
Destruction limit voltage
max. 30V
Current inputs
-
Max. input resistance (current range)
-
Input current ranges
-
Operational limit of current ranges
-
Operational limit of current ranges with SFU
-
Basic error limit current ranges
-
Radical error limit current ranges with SFU
-
Destruction limit current inputs (electrical current)
-
Destruction limit current inputs (voltage)
-
VIPA System MICRO
Hardware description
Technical data > Technical data CPU
HB400 | CPU | M13-CCF0000 | en | 16-47