Event ID
Description
ZInfo1 : Configuration not available
ZInfo1 : Configuration not valid
ZInfo1 : Refresh time too short
ZInfo1 : Cycle time too big
ZInfo1 : Not valid device number
ZInfo1 : CPU is configured as I device
ZInfo1 : Use different method to obtain IP address Is not supported for the IP address of the controller
ZInfo2 : Incompatible configuration (SDB version not supported)
ZInfo2 : EtherCAT: EoE configured but not supported
ZInfo2 : DC parameter not valid
0xEA65
Internal error - Please contact the hotline!
0xEA66
PROFINET error in communication stack
PK : Rack/slot
OB : StackError.Service
DatID : StackError.DeviceRef
ZInfo1 : StackError.Error.Code
ZInfo2 : StackError.Error.Detail
ZInfo3 : StackError.Error.AdditionalDetail
ZInfo3 : StackError.Error.AreaCode
0xEA67
PROFINET IO controller: Error reading record set
PK : Error type
0: Record set error local
1: Record set error stack
2: Record set error station
OB : Rack/slot of the controller
DatID : Device
ZInfo1 : Record set number
ZInfo2 : Record set handle (caller)
ZInfo3 : Internal error code from PN stack
0xEA68
PROFINET IO controller: Error at writing record set
PK : Error type
0: Record set error local
1: Record set error stack
2: Record set error station
OB : Rack/slot of the controller
DatID : Device
ZInfo1 : Record set number
ZInfo2 : Record set handle (caller)
VIPA System MICRO
System specific event IDs
HB400 | CPU | M13-CCF0000 | en | 16-47