Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-49
5.3
Setting Up the Servo Amplifier
This section describes the procedure for setting parameters to operate the SGDH
servo amplifier.
5.3.1
Parameters
The Sigma I
Ι
Series servo amplifier provides many functions and has parameters
that allow the user to specify functions and perform fine adjustments.
Parameters are divided into the following three groups.
Note: Appendix B shows a list of parameters provided for reference. See 7.1.6 Operation in Parameter Set-
ting Mode for more details on the procedure for setting parameters.
5.3.2
JOG Speed
Use the following parameter to set or modify motor speed when operating the servo-
motor from a panel or digital operator.
Use this parameter to set the motor speed when operating the servomotor from a
panel or digital operator. If the setting is higher than the maximum motor speed of
the servomotor, then the servomotor will rotate at its maximum speed.
Parameter
Function
Pn000 to Pn601
Specify servo amplifier functions, set servo gains, etc.
Fn000 to Fn012
Execute auxiliary functions such as JOG Mode operations
and origin searches.
Un000 to Un00D
Enable monitoring the motor speed and torque reference on
the panel display.
Parameter
Signal
Setting
(rpm)
Description
Pn304
Jog Speed
Setting Range: 0 to 10000
Default Setting: 500
Speed/Torque Control,
Position Control
Servo amplifier
Parameters
A panel operator or
digital operator is used
to set parameterts.