Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-34
2. Set the motor speeds with the following parameters.
These parameters are used to set motor speeds when the contact input speed con-
trol function is selected. If the setting is higher than the maximum motor speed
of the servomotor, then the servomotor will rotate at its maximum speed.
Speed selection input signals /P-CL(SPD-A)(CN1-45) and /N-CL (/SPD-B)
(CN1-46) and the rotation direction selection signal /P-CON (/SPD-D)(CN1-41)
enable the servomotor to run at the preset speeds.
3. Set the soft start time.
The servo amplifier internal speed reference controls speed by applying this acceler-
Parameter
Signal
Setting
(rpm)
Control Mode
Pn301
Speed 1 (SPEED 1)
(Contact Input Speed Control)
Range: 0 to 10000
Default Setting: 100
Speed Control
Pn302
Speed 2 (SPEED 2)
(Contact Input Speed Control)
Range: 0 to 10000
Default Setting: 200
Speed Control
Pn303
Speed 3 (SPEED 3)
(Contact Input Speed Control)
Range: 0 to 10000
Default Setting: 300
Speed Control
Parameter
Signal
Setting
(ms)
Control Mode
Pn305
Soft Start Acceleration Time
Setting Range: 0 to 10000
Default Setting: 0
Speed Control
Pn306
Soft Start Deceleration Time
Setting Range: 0 to 10000
Default Setting: 0
Speed Control
Contact Input Speed Control
Servo Amplifier
SPEED1
SPEED2
SPEED3
Servomotor
Servo operates
at the internally
set speed.
M