Sigma II User’s Manual
Appendix B: List of Parameters
B-10
B.4 Output Signal Selections
The following list shows output signal selections and their default settings.
Note 1.
When more than one signal is allocated to the same output circuit, data is output using OR logic.
2.
Depending on the control mode, undetected signals are treated as OFF. For example, in the speed
control mode, the /COIN signal is treated as OFF.
3.
Types of /WARN signals: Overload and regenerative overload.
Parameter
Digit
Place
Name
Setting
Description
Default
Setting
Pn50E
0
/COIN Signal Map-
ping
0
Disabled.
1: SO1
1
Outputs from the SO1 (CN1-25, 26) output terminal.
2
Outputs from the SO2 (CN1-27, 28) output terminal.
3
Outputs from the SO3 (CN1-29, 30) output terminal.
1
/V-CMP Signal
Mapping
0 to 3
Same as above
1: SO1
2
/TGON Signal Map-
ping
0 to 3
Same as above
2: SO2
3
/S-RDY Signal Map-
ping
0 to 3
Same as above
3: SO3
Pn50F
0
/CLT Signal Map-
ping
0 to 3
Same as above
0: Not
used
1
/VLT Signal Map-
ping
0 to 3
Same as above
2
/BK Signal Map
ping
0 to 3
Same as above
3
/WARN Signal Map-
ping
0 to 3
Same as above
Pn510
0
/NEAR Signal Map-
ping
0 to 3
Same as above
1
Reserved
0 to 3
Same as above
2
Not used.
0
—
0
3
Not used.
0
—
0
Pn512
0
Output Signal
Reversal for SO1
(CN-25 and 26)
0
Output signal is not reversed.
0: Not
reversed
1
Output signal is reversed.
1
Output Signal
Reversal for SO1
(CN-25 and 26)
0
Output signal is not reversed.
1
Output signal is reversed.
2
Output Signal
Reversal for SO1
(CN-25 and 26)
0
Output signal is not reversed.
1
Output signal is reversed.
3
Not used.
—
—
0