9 Appendix
9.1.2 Parameters
9-20
Pn512
Output Signal Inverse Setting
0000 to 0111
−
0000
After restart
Setup
3.3.2
Pn513
Reserved Parameter (Do not change.)
–
–
0000
–
–
–
Pn517
Reserved Parameter (Do not change.)
–
–
0000
–
–
–
Pn51E
Excessive Position Error Warning
Level
10 to 100
1%
100
Immediately
Setup
8.2.1
Pn520
Excessive Position Error Alarm Level
1 to
1073741823
(2
30
-1)
1
reference
unit
5242880
Immediately
Setup
5.1.4
8.1.1
Pn522
Positioning Completed Width
0 to
1073741824
(2
30
)
1
reference
unit
7
Immediately
Setup
–
Pn524
NEAR Signal Width
1 to
1073741824
(2
30
)
1
reference
unit
1073741824
Immediately
Setup
–
Pn526
Excessive Position Error Alarm Level
at Servo ON
1 to
1073741823
(2
30
-1)
1
reference
unit
5242880
Immediately
Setup
5.1.4
8.1.1
Pn528
Excessive Position Error Warning
Level at Servo ON
10 to 100
1%
100
Immediately
Setup
8.2.1
Pn52B
Overload Warning Level
1 to 100
1%
20
Immediately
Setup
4.2.12
Pn52C
Derating of Base Current at Detecting
Overload of Motor
10 to 100
1%
100
After restart
Setup
Pn52F
Monitor Display at Power ON
0000 to 0FFF
−
0FFF
Immediately
Setup
–
Parameter
No.
Name
Setting
Range
Units
Factory
Setting When Enabled Classification
Refer-
ence
Section
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
Output Signal Inversion for CN1-1 or -2 Terminals
0
1
Does not inverse outputs.
Inverses outputs.
Output Signal Inversion for CN1-23 or -24 Terminals
0
1
Does not inverse outputs.
Inverses outputs.
Output Signal Inversion for CN1-25 or -26 Terminals
0
1
Does not inverse outputs.
Inverses outputs.
Reserved (Do not change.)