9.2 Monitor Modes
9-23
9
Appendix
9.2
Monitor Modes
The following list shows monitor modes available.
∗1.
For details, refer to
4.2.4 Electronic Gear
.
∗2.
Scale pitch = Un084
×
10
Un085
[pm]
Parameter
No.
Content of Display
Unit
Un000
Motor movement speed
mm/s
Un001
Speed reference (for speed control)
mm/s
Un002
Internal force reference (in percentage to the rated force)
%
Un003
Electric angle 1
pulse (linear scale resolution)
Un004
Electric angle 2 (angle from the polarity origin)
deg
Un005
Input signal monitor
−
Un006
Output signal monitor
−
Un007
Reference speed (for position control)
mm/s
Un008
Position error (for position control)
reference unit
Un009
Accumulated load ratio (in percentage to the rated force: effec-
tive force in cycle of 10 seconds)
%
Un00A
Regenerative load ratio (in percentage to the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)
%
Un00B
Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
played in cycle of 10 seconds)
%
Un00C
Reference counter
reference unit
Un00D
Feedback pulse counter
pulse (linear scale resolution)
*1
Un010
Maximum allowable motor speed or maximum allowable
encoder output resolution
−
Un011
Hall sensor signal monitor
−
Un012
Total operation time
100 ms
Un013
Feedback pulse counter
reference unit
Un014
Effective gain monitor (gain setting 1 = 1, gain setting 2 = 2)
−
Un015
Safety I/O signal monitor
−
Un020
Motor rated speed
mm/s
Un021
Motor maximum speed
mm/s
Un084
Linear scale pitch
*2
pm
Un085
Linear scale pitch index
*2
−