3.2 Operating Procedures for Utility Functions
3.2.2 Jog (Fn002)
3-11
3
Utility Function
s
Operating Procedure
The following procedure shows how to jog the motor at a jogging speed
of 1,000 min
-1
. (The default setting is 500 min
-1
.)
Step
Operation
Result
1
Press the
Key to display the
Utility Mode Main Menu, and then
use the
Key or
Key to
select
Fn002
.
2
Press the
Key.
The Fn002 (Jog) execution display
will appear.
3
Press the
Key.
The cursor will move to the setting
for Pn304 (Jogging Speed).
4
Use the
Key,
Key,
Key, and
Key to set Pn304
(Jogging Speed) to 1,000.
5
Press the
Key.
The setting will be saved and the
cursor will move to the parameter
number.
Continued on next page.