3.2 Operating Procedures for Utility Functions
3.2.32 Vibration Suppression (Fn205)
3-101
3
Utility Function
s
Operating Procedure
Step
Operation
Result
1
Input an operation reference,
repeatedly perform a positioning
operation, and perform steps 2 on.
–
2
Press the
Key to display the
Utility Mode Main Menu, and then
use the
Key or
Key to
select
Fn205
.
3
Press the
Key.
The frequency will be detected and
the following display will appear.
The detected frequency is displayed
at
Measure f
.
The setting frequency is displayed
at
Setting f
. The default value is the
setting of Pn145 (Vibration Sup-
pression 1 Frequency A).
Note: 1. If the setting frequency and
actual operating frequency are
different,
Setting
will flash.
2. Frequency detection will not be
performed if there is no vibra-
tion or if the vibration frequency
is outside the range of detect-
able frequencies. The following
display will appear.
If a vibration frequency is not
detected, prepare a means
of detecting and measuring
the vibration. If you measure
the vibration frequency, go to
step 5 and manually set the
measured vibration fre-
quency at
Setting f
.
Continued on next page.
1 : R U N F U N C T I O N
F n 2 0 4 : A - V i b
S
u p
F n 2 0 5 : V i b
S
u p
F n 2 0 6 : E a
s
y F F T
F n 2 0 7 : V - M o n i t o r
1 : R U N V i b
S
u p
M e a
s
u r e f = 0 1 0 . 4 Hz
S
e t t i n g f = 0 5 0 . 0 Hz
1 : R U N V i b
S
u p
M e a
s
u r e f = - - - - - Hz
S
e t t i n g f = 0 5 0 . 0 Hz