3.2 Operating Procedures for Utility Functions
3.2.31 Adjust Anti-resonance Control (Fn204)
3-98
Fine-Tuning after Adjusting Anti-resonance Con-
trol
9
Use the
Key or
Key to
move the cursor and the
Key
or
Key to fine-tune the fre-
quency.
10
Press the
Key.
Note: Press the
Key to cancel
saving the data. The display will
return to the status shown in step
1.
The adjusted settings will be saved
in the SERVOPACK. The status dis-
play will flash
DONE
as shown
below for approximately one sec-
ond and then return to
1:RUN
.
Step
Operation
Result
1
Press the
Key to display the
Utility Mode Main Menu, and then
use the
Key or
Key to
select
Fn204
.
2
Press the
Key.
The following display will appear.
Note: If the initial setting display does not
appear and the status display
changes to
NO-OP
, refer to the
following section and correct the
problem.
3.2.31 Adjust Anti-reso-
nance Control (Fn204)
-
Continued on next page.
Continued from previous page.
Step
Operation
Result
1 : R U N V i b
S
u p
f r e q = 0 4 0 0 H z
d a m p = 0 1 2 0
D O N E V i b
S
u p
f r e q = 0 4 0 0 H z
d a m p = 0 1 2 0
1 : R U N F U N C T I O N
F n 2 0
3
: O n e P r m T u n
F n 2 0 4 : A - V i b
S
u p
F n 2 0 5 : V i b
S
u p
F n 2 0 6 : E a
s
y F F T
1 : R U N F U N C T I O N
T u n i n g M o d e = 1