
14.1 List of Parameters
14.1.2 List of Parameters
14-20
Pn426
2
Torque Feedforward
Average Movement
Time
0 to 5,100
0.1 ms
0
All
Immedi-
ately
Setup
−
Pn427
2
Speed Ripple Compen-
sation Enable Speed
0 to 10,000
1 min
-1
0
Rotary Ser-
vomotor
Immedi-
ately
Tuning
−
Pn456
2
Sweep Torque Refer-
ence Amplitude
1 to 800
1%
15
All
Immedi-
ately
Tuning
Pn460
2
Notch Filter Adjustment
Selections 1
0000 to
0101
−
0101
All
Immedi-
ately
Tuning
Pn480
2
Speed Limit during
Force Control
0 to 10,000
1 mm/s
10000
Linear
Immedi-
ately
Setup
Pn481
2
Polarity Detection
Speed Loop Gain
10 to 20,000
0.1 Hz
400
Linear
Immedi-
ately
Tuning
–
Pn482
2
Polarity Detection
Speed Loop Integral
Time Constant
15 to 51,200 0.01 ms
3000
Linear
Immedi-
ately
Tuning
–
Pn483
2
Forward Force Limit
0 to 800
1%
*1
30
Linear
Immedi-
ately
Setup
Pn484
2
Reverse Force Limit
0 to 800
1%
*1
30
Linear
Immedi-
ately
Setup
Pn485
2
Polarity Detection Refer-
ence Speed
0 to 100
1 mm/s
20
Linear
Immedi-
ately
Tuning
–
Pn486
2
Polarity Detection Refer-
ence Acceleration/
Deceleration Time
0 to 100
1 ms
25
Linear
Immedi-
ately
Tuning
–
Pn487
2
Polarity Detection Con-
stant Speed Time
0 to 300
1 ms
0
Linear
Immedi-
ately
Tuning
–
Pn488
2
Polarity Detection Refer-
ence Waiting Time
50 to 500
1 ms
100
Linear
Immedi-
ately
Tuning
–
Pn48E
2
Polarity Detection
Range
1 to 65,535
1 mm
10
Linear
Immedi-
ately
Tuning
–
Pn490
2
Polarity Detection Load
Level
0 to 20,000
1%
100
Linear
Immedi-
ately
Tuning
–
Pn495
2
Polarity Detection Con-
firmation Force Refer-
ence
0 to 200
1%
100
Linear
Immedi-
ately
Tuning
–
Pn498
2
Polarity Detection Allow-
able Error Range
0 to 30
1 deg
10
Linear
Immedi-
ately
Tuning
–
Pn49F
2
Speed Ripple Compen-
sation Enable Speed
0 to 10,000
1 mm/s
0
Linear
Immedi-
ately
Tuning
–
Pn501
2
Zero Clamping Level
0 to 10,000
1 min
-1
10
Rotary
Immedi-
ately
Setup
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Notch Filter Adjustment Selection 1
0
Do not adjust the first stage notch filter automatically during execution of auto-
tuning without a host reference, autotuning with a host reference, and custom
tuning.
1
Adjust the first stage notch filter automatically during execution of autotuning
without a host reference, autotuning with a host reference, and custom tuning.
n.
X
Reserved parameter (Do not change.)
n.
X
Notch Filter Adjustment Selection 2
0
Do not adjust the second stage notch filter automatically during execution of
autotuning without a host reference, autotuning with a host reference, and
custom tuning.
1
Adjust the second stage notch filter automatically during execution of autotun-
ing without a host reference, autotuning with a host reference, and custom
tuning.
n.X
Reserved parameter (Do not change.)